Investigation On Static And Dynamic Performance Of A Hinge Configuration With Integrated Dielectric Elastomers
chi zhang,hualing chen,bo li,yanjie wang,lei liu,dichen li
DOI: https://doi.org/10.1002/app.41630
IF: 3
2015-01-01
Journal of Applied Polymer Science
Abstract:A rigid hinge frame combined with pre-stretched dielectric elastomer (DE) films can form an active biological agonist-antagonist configuration. In this structure, the DE films undergo a constant deformation under a static voltage as well as specific reciprocating rotation under an alternative voltage. To theoretically investigate the static and dynamic performance, we establish the kinetic equation of the active hinge configuration. The computational static rotary angle exhibits a good fit with the experimental data from literature. Based on this model, static performance of this configuration when DE undergoes uniaxial and pure shear deformation is investigated. Subject to a small perturbation, the configuration may oscillate around the equilibrium state and the natural frequency can be obtained. By varying the pre-stretch ratios, applied voltage, layer number, and the rotational inertia of the hinge, we can tune the natural frequency at a wide range. When the voltage is sinusoidal and varies continuously, the configuration resonates at multiple frequencies of excitation, known as harmonic and superharmonic resonance. Our research may serve as a guide to optimal design and provide insights into the performance of the hinge configuration, which can effectively expand the structure's application fields. (c) 2014 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 2015, 132, 41630.