Solving the cost minimization problem of optimal reactive power dispatch in a renewable energy integrated distribution system using rock hyraxes swarm optimization

Das, Tanmay,Roy, Ranjit
DOI: https://doi.org/10.1007/s00202-024-02548-9
IF: 1.63
2024-06-27
Electrical Engineering
Abstract:The optimal reactive power dispatch problem optimizes the shunt capacitor bank installation in distribution systems, reducing power loss and also reducing the financial loss for the electricity market associated with power loss. Moreover, the sharing of both active and reactive power from different renewable energy sources like PV and wind in the form of distributed generation also contributes toward reducing power loss and improving the voltage profile of the system. But the installation and maintenance costs associated with these additional set-ups are rarely taken into consideration any optimization problem. This paper aims to reduce the power loss and improve the voltage profile of a radial distribution network with the integration of capacitor banks, PV, and wind energy sources, while taking into account the overall associated cost of each parameter during optimization. The problem is formulated as a novel cost minimization problem aiming to achieve the optimal settings for a life-long capacitor bank-PV-wind integrated distribution network with the least possible installation, operational, and maintenance costs while reducing its power loss significantly for a span of 20 years. The uncertain nature of PV and wind power output has been modeled using the beta probability distribution function and the Weibull probability distribution function, respectively. This unique proposed problem statement of the capacitor bank-PV-wind power integrated distribution network has been tested on the IEEE 33 and IEEE 141 bus systems and solved using the rock hyraxes swarm optimization (RHSO) algorithm. The results were compared with those from other nine well-established techniques, from which it was concluded that the RHSO algorithm has obtained optimal conditions for both systems to operate efficiently. The problem has also been tested on a practical 13-bus 33 kV distribution network in Maharashtra, India, to validate its performance on a practical system. The RHSO has successfully reduced the power loss to almost 17.48% w.r.t. the base case for the practical network while maintaining a minimum overall cost of $51,073,687.7582 for an entire life-span of 20 years.
engineering, electrical & electronic
What problem does this paper attempt to address?