Equivalence of flexible stripline and coaxial cables for superconducting qubit control and readout pulses

V. Y. Monarkha,S. Simbierowicz,M. Borrelli,R. van Gulik,N. Drobotun,D. Kuitenbrouwer,D. Bouman,D. Datta,P. Eskelinen,E. Mannila,J. Kaikkonen,V. Vesterinen,J. Govenius,R. E. Lake
DOI: https://doi.org/10.1063/5.0203101
IF: 4
2024-05-27
Applied Physics Letters
Abstract:We report a comparative study on microwave control lines for a transmon qubit using (i) flexible stripline transmission lines and (ii) semi-rigid coaxial cables. During each experiment, we performed repeated measurements of the energy relaxation and coherence times of a transmon qubit using one of the wiring configurations. Each measurement run spanned 70–250 h of the measurement time, and four separate cooldowns were performed so that each configuration could be tested twice. From these datasets, we observe that changing the microwave control lines from coaxial cables to flexible stripline transmission lines does not have a measurable effect on coherence compared to thermal cycling the system or random coherence fluctuations. Our results open up the possibility of large-scale integration of qubit control lines with integrated component with planar layouts on flexible substrate.
physics, applied
What problem does this paper attempt to address?