Investigating retinal toxicity of tempol in a model of isolated and perfused bovine retina

Kai Januschowski,Sebastian Mueller,Rebecca Dollinger,Sven Schnichels,Johanna Hofmann,Martin S. Spitzer,Karl-Ulrich Bartz-Schmidt,Peter Szurman,Sebastian Thaler
DOI: https://doi.org/10.1007/s00417-014-2632-4
2014-05-02
Abstract:PurposeTempol (4-hydroxy-2,2,6,6-tetramethylpiperidinyl-1-oxyl) is a membrane-permeable superoxide dismutase and potentially neuroprotective substance. This study evaluates the retinal tolerance of 0.5 mM, 1 mM, 2 mM, and 5 mM tempol measured by the electroretinogram (ERG) of an isolated and perfused retina whole mount.MethodsFor functionality testing, bovine retinas were prepared and perfused with an oxygen-saturated standard solution, and the ERG was recorded until stable b-wave amplitudes were reached. Tempol concentrations of 0.5 mM, 1 mM, 2 mM, and 5 mM were tested for 45 minutes. To investigate the effects on photoreceptor function, 1 mM aspartate was added to suppress the b-wave and obtain isolated a-waves. ERG amplitudes were monitored for 100 minutes.ResultsWhile no toxic effects for concentrations of 0.5 mM and 1 mM tempol could be detected, concentrations of 2 mM tempol and higher caused statistically significant negative effects on the b-wave amplitude (−38 %, p = 0.02 for 2 mM; −54 %, p = 0.02 for 5 mM). The a-wave amplitude remained stable even at higher concentrations.ConclusionsAlthough the photoreceptors seem to have a tolerance to high concentrations of tempol, higher intravitreal concentrations than 1 mM should be considered critical.
What problem does this paper attempt to address?