Formaldehyde Derivatization: An Unexpected Side Reaction During Filter-Aided Sample Preparation

Langlang Tang,Zhen Wu,Jie Wang,Xumin Zhang
DOI: https://doi.org/10.1021/acs.analchem.0c01981
IF: 7.4
2020-08-12
Analytical Chemistry
Abstract:The filter-aided sample preparation (FASP) method has been commonly used for proteomic sample preparation due to its high efficiency in removing impurities. Herein, we report an overlooked +12 Da side modification during FASP method using Microcon spin filters. We confirmed that the side modification is caused by formaldehyde released from the spin filter and found that the side modification leads to 10.5% and 9.5% loss in proteome-level peptide and protein identification, respectively. We evaluated different pretreatment procedures to reduce the side reaction. Furthermore, on the basis of the evaluation results of different brands of spin filters, we recommend Nanosep spin filters for different proteomic studies, especially for amine-labeling proteomic studies. Our results would benefit researchers employing the spin filters to improve their results and also help spin filter manufacturers to improve the product quality. Data are available via ProteomeXchange with identifier PXD018737.The Supporting Information is available free of charge at <a class="ext-link" href="/doi/10.1021/acs.analchem.0c01981?goto=supporting-info">https://pubs.acs.org/doi/10.1021/acs.analchem.0c01981</a>.Detailed identification lists by different FASP digestion methods (<a class="ext-link" href="/doi/suppl/10.1021/acs.analchem.0c01981/suppl_file/ac0c01981_si_001.xlsx">XLSX</a>)Observation of +12 Da modification in published studies (<a class="ext-link" href="/doi/suppl/10.1021/acs.analchem.0c01981/suppl_file/ac0c01981_si_002.xlsx">XLSX</a>)Detailed identification lists of FASP method using different brands of spin filters (<a class="ext-link" href="/doi/suppl/10.1021/acs.analchem.0c01981/suppl_file/ac0c01981_si_003.xlsx">XLSX</a>)MALDI-TOF MS analysis of the BSA tryptic peptides by in-tube digestion with different buffers (Figure S1); Comparisons of MS/MS spectra of the original peptides and the +12 Da modified peptides (Figure S2); CH<sub>2</sub>O causes +12 Da side modification (Figure S3); Test using a synthetic peptide (Figures S4 and S5); Detailed digestion protocols (<a class="ext-link" href="/doi/suppl/10.1021/acs.analchem.0c01981/suppl_file/ac0c01981_si_004.pdf">PDF</a>)This article has not yet been cited by other publications.
chemistry, analytical
What problem does this paper attempt to address?