Matched case–control comparison of surgical success after XEN45 Gel Stent and PRESERFLO MicroShunt implantation in a Caucasian population

Jan Niklas Lüke,Thomas S. Dietlein,Randolf A. Widder,Gernot F. Roessler,Vincent Lüke,Philip Enders,Alexandra Lappa,David Kiessling
DOI: https://doi.org/10.1111/ceo.14407
2024-06-08
Clinical and Experimental Ophthalmology
Abstract:Background The aim of this study was to compare the outcome of implantation of a XEN45 Gel Stent with the outcome of implantation of a Preserflo MicroShunt in a matched‐pair analysis in eyes being naïve to filtering surgery. Methods In this comparative, retrospective study, 50 eyes that had undergone XEN45 Gel Stent implantation were compared with 50 eyes after Preserflo implantation. Follow‐up was at least 6 months, and surgical success was measured by criteria A (IOP 20%, no repeat surgery); criteria B (IOP 20%, no repeat surgery); and criteria C (IOP ≤15 mmHg, IOP reduction ≥40%, no repeat surgery). Results After a follow‐up period of 12 months, mean IOP had decreased from preoperative 25.2 ± 4.8 mmHg in the XEN group to 14.5 ± 4.0 (n = 35) and from 25.3 ± 6.8 mmHg to 11.9 ± 2.9 (n = 41) in the Preserflo group, respectively. The IOP at the last follow‐up of the two groups differed significantly (p
ophthalmology
What problem does this paper attempt to address?