Methodology for Preventing Drill String Fatigue Failure in Deep Well with Large Shallow Dogleg

Wenxing Deng,Hailiang Li,Hongchun Huang,Guodong Ji,Lingzhan Zou,Qing Wang,Jiawei Zhang,Xusheng He
DOI: https://doi.org/10.2523/iptc-23191-ms
2024-02-12
Abstract:Fatigue failure is recognized as the primary cause of tubular twist-off. Repeated cyclic bending loads and stress caused by dogleg severity, pipe weight and buckled drill pipes would result in drill string fatigue failure as seven twist-off accidents have been observed at large shallow dogleg sections in three deep wells with TVD (True Vertical depth) more than 5000m. Fishing jobs, plug-back and sidetracking operations were time-consuming and costly, while typical inspection and cumulative pumping hours can't determine the thresholds for preventing drill string fatigue failure in such scenario. This paper proposes the methodology for preventing drill string fatigue failure in deep wells with large shallow dogleg. The relative fatigue index prediction model is established based on drill string stress characteristics and crack propagation behavior, on the basis of which cumulative fatigue distribution of entire drill string in drilled or pre-drill intervals could be calculated. Considering the added cumulative fatigue for drill string from drilled intervals, methods and procedures including optimizing drilling parameters, reshuffling drill string, replacing with new drill string are proposed for preventing fatigue failure in pre-drill interval. One of the filed applications was carried out in one deep well, which suffered from two drill string failures consecutively with failure position at same large shallow dogleg section. The calculated cumulative fatigue index of the second failure based on actual drilling data was 1.0595, which verified the accuracy of established model for predicting drill string fatigue failure. Also, simulation results showed that cumulative fatigue index rose rapidly when drilling through large shallow dogleg section, which justified all failure positions occurred at same large shallow dogleg section. Cumulative fatigue distribution of entire drill string was determined after two consecutively failures, suggesting that the drill string would have had to been reshuffled constantly with shrinking drilling interval if the remaining well section had been drilled with used drill pipes. After replacing with new drill string, simulation showed that maximum cumulative fatigue index would have been less than 0.35 if the remaining well section had been drilled with RPM lower than 60r/min and ROP higher than 3m/h by reaching design depth. The remaining well section was drilled without accident by just one interval with actual RPM within 30-40r/min and ROP within 3-11m/h. The established model could serve as an effective method to evaluate cumulative fatigue distribution of entire drill string, based on which proposed methodology could help to prevent drill string fatigue failure for deep well with large shallow dogleg.
Environmental Science,Engineering
What problem does this paper attempt to address?