The adherence to an intraoperative blood product transfusion algorithm is associated with reduced blood product transfusions in cardiac surgical patients undergoing coronary artery bypass grafts and aortic and or valve replacement surgery: A single-center, observational study

Megan Lanigan,Daniel Siers,Megan Schramski,Andrew Shaffer,Ranjit John,Ryan Knoper,Stephen Huddleston,Lauren Gunn-Sandell,Alexander Kaizer,Tjorvi E Perry
DOI: https://doi.org/10.1053/j.jvca.2024.01.029
IF: 2.894
2024-02-02
Journal of Cardiothoracic and Vascular Anesthesia
Abstract:Objective(s) To demonstrate the value of a viscoelastic-based intraoperative transfusion algorithm to reduce blood product administration in adult cardiac surgical patients. Design Prospective observational. Setting Quaternary academic teaching hospital. Participants Cardiac surgical patients. Interventions Viscoelastic-based intraoperative transfusion algorithm. Measurements and Main Results We compared intraoperative blood product transfusion rates in 184 cardiac surgical patients to 236 historical controls after implementing a viscoelastic-based algorithm. We found a 43.9% reduction in RBC units transfused (1.98 units ±2.24 vs 0.55 ±1.36; p=0.008). We found a reduction in transfusion of 23.8% for FFP (0.84 units ±1.4 vs 0.64 ±1.38; p=ns), 33.4% for platelets (0.90 units ±1.39 vs 0.60 ±131; p=ns), and 15.8% for cryoprecipitate (0.19 units ±0.54 vs 0.16 ±0.50; p=ns). There was no statistically significant difference in time to extubation (8.0 hours [4.0, 21.0] vs 8.0 [4.0, 22.3], reoperation for bleeding (15 (12.3%) vs 10 (10.6%), ICU LOS (51.0 hours [28.0, 100.5] vs. 53.5 [33.3, 99.0]) or hospital length of stay (9.0 days [6.0, 15.0] vs. 10.0 [7.0, 17.0]). Deviation from algorithm adherence was 32.7% (48/147). PRBC, FFP, platelets, cryoprecipitate and cell saver were significantly reduced in the Algorithm Compliant Cohort compared with Historical Controls while times to extubation, ICU and hospital lengths of stay did not reach significance. Conclusions Following implementation of a viscoelastic-based algorithm, patients received fewer PRBC, FFP, platelets, cryoprecipitate and cell saver. Algorithm Compliant patients received fewer transfusions; however, reductions in times to extubation, ICU and hospital lengths of stay were not statistically significant compared with historical controls.
cardiac & cardiovascular systems,peripheral vascular disease,respiratory system,anesthesiology
What problem does this paper attempt to address?