Beam test performance of the highly granular SiW-ECAL technological prototype for the ILC

K. Kawagoe,Y. Miura,I. Sekiya,T. Suehara,T. Yoshioka,S. Bilokin,J. Bonis,P. Cornebise,A. Gallas,A. Irles,R. Pöschl,F. Richard,A. Thiebault,D. Zerwas,M. Anduze,V. Balagura,V. Boudry,J-C. Brient,E. Edy,G. Fayolle,M. Frotin,F. Gastaldi,R. Guillaumat,A. Lobanov,M. Louzir,F. Magniette,J. Nanni,M. Rubio-Roy,K. Shpak,H. Videau,D. Yu,S. Callier,F. Dulucq,Ch. de la Taille,N. Seguin-Moreau,J.E. Augustin,R. Cornat,J. David,P. Ghislain,D. Lacour,L. Lavergne,J.M. Parraud,J.S. Chai,D. Jeans
DOI: https://doi.org/10.1016/j.nima.2019.162969
2020-01-01
Abstract:<p>The technological prototype of the CALICE highly granular silicon–tungsten electromagnetic calorimeter (SiW-ECAL) was tested in a beam at DESY in 2017. The setup comprised seven layers of silicon sensors. Each layer comprised four sensors, with each sensor containing an array of 256 <span class="math"><math>5.5×5.5</math></span> mm<span class="math"><math>2</math></span> silicon PIN diodes. The four sensors covered a total area of 18 × 18 cm and comprised a total of 1024 channels. The readout was split into a trigger line and a charge signal line. Key performance results for signal over noise for the two output lines are presented, together with a study of the uniformity of the detector response. Measurements of the response to electrons for the tungsten loaded version of the detector are also presented.</p>