Cd2+-Selective Fluorescence Enhancement of Bisquinoline Derivatives with 2-Aminoethanol Skeleton

Yuji Mikata,Aya Tsuruta,Hinata Koike,Sunao Shoji,Hideo Konno
DOI: https://doi.org/10.3390/molecules29020369
IF: 4.6
2024-01-12
Molecules
Abstract:The development of fluorescent Cd2+ sensors requires strict selectivity over Zn2+ because of the high availability of Zn2+ in the natural environment. In this paper, bisquinoline-based fluorescent sensors with a 2-aminoethanol backbone were investigated. The weak coordination ability of quinoline compared to well-studied pyridine is suitable for Cd2+ selectivity rather than Zn2+. In the presence of 3 equiv. of metal ions, TriMeO-N,O-BQMAE (N,O-bis(5,6,7-trimethoxy-2-quinolylmethyl)-2-methylaminoethanol (3)), as well as its N,N-isomer TriMeO-N,N-BQMAE (N,N-bis(5,6,7-trimethoxy-2-quinolylmethyl)-2-methoxyethylamine (6)), exhibits Cd2+-selective fluorescence enhancement over Zn2+ in DMF-HEPES buffer (1:1, 50 mM HEPES, 0.1 M KCl, pH = 7.5) (IZn/ICd = 26–34%), which has similar selectivity in comparison to the corresponding ethylenediamine derivative TriMeOBQDMEN (N,N'-bis(5,6,7-trimethoxy-2-quinolylmethyl)-N,N'-dimethylethylenediamine) under the same experimental condition (IZn/ICd = 24%). The fluorescence mechanisms of N,O- and N,N-isomers of BQMAE are quite different, judging from the fluorescence lifetimes of their metal complexes. The Cd2+ complex with TriMeO-N,O-BQMAE (3) exhibits a long fluorescence lifetime similar to that of TriMeOBQDMEN via intramolecular excimer emission, whereas the Cd2+ complex with TriMeO-N,N-BQMAE (6) exhibits a short lifetime from monomer emission.
chemistry, multidisciplinary,biochemistry & molecular biology
What problem does this paper attempt to address?
The problem this paper attempts to address is the development of a highly selective fluorescent sensor for Cd²⁺, especially in the presence of high concentrations of Zn²⁺ in natural environments. Specifically, the researchers designed and synthesized bis-quinoline derivatives based on a 2-aminoethanol framework (N,O-BQMAE and N,N-BQMAE) and experimentally verified the fluorescence enhancement properties of these derivatives in the presence of different metal ions. ### Main Issues: 1. **Selective Detection of Cd²⁺**: Due to the very close ionic radii of Cd²⁺ and Zn²⁺ (differing by only 21 pm), developing a fluorescent sensor that can distinguish between these two metal ions is a challenge. 2. **Exploration of Fluorescence Mechanism**: The researchers aim to understand the fluorescence mechanism of these derivatives when forming complexes with Cd²⁺ and Zn²⁺ through experimental data, particularly the differences in fluorescence lifetime. ### Solutions: 1. **Designing New Fluorescent Probes**: The researchers designed bis-quinoline derivatives containing a 2-aminoethanol framework, including N,O-BQMAE and N,N-BQMAE, and synthesized these compounds. 2. **Experimental Verification**: The fluorescence response of these derivatives in the presence of different metal ions was studied using fluorescence spectroscopy, absorption spectroscopy, and fluorescence lifetime measurements. 3. **Performance Evaluation**: The selectivity and limit of detection (LOD) of these derivatives for Cd²⁺ were evaluated and compared with existing fluorescent sensors. ### Key Findings: 1. **Enhanced Selectivity**: In DMF-HEPES buffer, the trimethoxy-substituted N,O-BQMAE derivative (TriMeO-N,O-BQMAE) exhibited selective fluorescence enhancement for Cd²⁺ (IZn/ICd = 34%), although the selectivity was slightly lower than the known TriMeOBQDMEN (IZn/ICd = 24%). 2. **Fluorescence Lifetime Differences**: N,O-BQMAE derivatives showed a longer fluorescence lifetime (about 30 nsec) when forming complexes with Cd²⁺, while the fluorescence lifetime was shorter (about 22 nsec) when forming complexes with Zn²⁺. This suggests that N,O-BQMAE derivatives may form specific dinuclear cadmium complexes. 3. **pH Stability**: The effect of pH on fluorescence intensity was studied, and it was found that TriMeO-N,N-BQMAE exhibited stable fluorescence intensity between pH 4 and 11, making it suitable for practical applications. 4. **Limit of Detection**: The limit of detection (LOD) for TriMeO-N,N-BQMAE was 17 nM, which is lower than the cadmium limit in Japanese water environments (3 ppb, 27 nM), demonstrating good potential for practical applications. In summary, this paper successfully improved the selective detection capability for Cd²⁺ by designing and synthesizing new fluorescent probes and thoroughly explored their fluorescence mechanism, providing a powerful tool for environmental monitoring and bioanalysis.