The excess loss analysis of an easy-plane FeSiAl@SiO 2 soft magnetic composite with high permeability

Hang Zhang,Ke Wang,Yuandong Huang,Chenhu Zhang,Ying Wang,Tao Wang
DOI: https://doi.org/10.1016/j.jmmm.2023.171471
IF: 3.097
2023-11-10
Journal of Magnetism and Magnetic Materials
Abstract:The loss coming from the special eddy current caused by the inhomogeneous domain wall motion is usually used to explain the complex mechanisms of the excess loss below 200 kHz. In this work, an easy-plane FeSiAl@SiO 2 SMC was fabricated to analyze the core loss. The prepared easy-plane FeSiAl@SiO 2 SMC exhibits an initial permeability of 816 at 1 MHz and a domain wall resonance peak of 5.9 MHz. The core loss was measured up to 3 MHz and was separated into hysteresis loss, classical eddy current loss and excess loss. The excess loss was deeply analyzed by the theory of G. Bertotti. The results show the excess loss caused by localized eddy curreny is the main component of core loss in the range of 200 kHz to 3 MHz, and the domain wall resonance also exhibits the contribution on the core loss in the MHz band.
materials science, multidisciplinary,physics, condensed matter
What problem does this paper attempt to address?