Sludge yield and degradation of suspended solids by a large pilot-scale anaerobic membrane bioreactor for the treatment of real municipal wastewater at 25 °C

Zhe Kong,Jiang Wu,Chao Rong,Tianjie Wang,Lu Li,Zibin Luo,Jiayuan Ji,Taira Hanaoka,Shinichi Sakemi,Masami Ito,Shigeki Kobayashi,Masumi Kobayashi,Yu Qin,Yu-You Li
DOI: https://doi.org/10.1016/j.scitotenv.2020.143526
2021-03-01
Abstract:Sludge yield and suspended solid are important factors concerned in the anaerobic treatment of municipal wastewater. In this study, a large pilot-scale anaerobic membrane bioreactor (AnMBR) was constructed for effectively treating real municipal wastewater at an ambient temperature of 25 °C. The sludge yield and the degradation of influent suspended solids were evaluated during the long-term operation of the AnMBR. This reactor with 5.0 m<sup>3</sup> effective volume is the largest one-stage submerged AnMBR that has ever been used to treat municipal wastewater. During the long-term operation of 217 days, this AnMBR obtained excellent COD and BOD<sub>5</sub> removal efficiency over 90%. Stable biogas production was also successfully obtained from treating municipal wastewater. The sludge yield of the AnMBR was approximately 0.19-0.26 g MLSS g<sup>-1</sup> COD removed for the treatment of real municipal wastewater. The shortest SRT of the AnMBR was calculated as 29 days for an HRT of 6 h at an empirical MLSS of 10 g L<sup>-1</sup>. While the influent suspended solid (SS) contained in the municipal wastewater was completely removed by the AnMBR, only 57%-66% of the influent SS was degraded. The rest of influent SS was directly converted to MLSS instead of being degraded. The AnMBR maintained a stable membrane filtration using a hollow-fiber membrane with a total area of 72 m<sup>2</sup>, realizing a flux of 2.75-17.83 LMH, and the mean transmembrane pressure (TMP) was 0.9-23.5 kPa. An online chemical backwash cleaning system helped to lower the TMP timely using sodium hypochlorite and citric acid when the TMP increased rapidly and reached the rated limit of membrane. This is the first report on demonstrating the successful operation and detailed performance of a large pilot-scale AnMBR applied to the treatment of real municipal wastewater.
environmental sciences
What problem does this paper attempt to address?
The main problem that this paper attempts to solve is to evaluate and verify the performance and feasibility of large - scale anaerobic membrane bioreactors (AnMBR) in treating actual municipal sewage. Specifically, the research aims to: 1. **Demonstrate and investigate the long - term wastewater treatment performance and biogas production of large - scale anaerobic membrane bioreactors (AnMBR) in treating actual municipal sewage at 25°C**: - The research achieves this goal through a large - scale pilot - scale first - stage submerged AnMBR with an effective volume of 5.0 cubic meters. - This reactor continuously treats actual municipal sewage within 217 days, evaluating its COD and BOD5 removal efficiencies under different hydraulic retention times (HRT) and stable biogas production. 2. **Evaluate the actual sludge production of large - scale anaerobic membrane bioreactors in treating actual municipal sewage**: - The research measures the amount of sludge produced per gram of COD removed and finds that the sludge production is approximately 0.19 to 0.26 grams of MLSS per gram of COD removed. - It further explores the degradation of influent suspended solids (SS) and finds that although the influent SS is completely removed, only 57% to 66% of the SS is degraded, and the rest is directly converted into MLSS. 3. **Further explore the obstacles and problems that occur during the operation**: - These include insufficient degradation of influent SS and membrane fouling control. - The transmembrane pressure difference (TMP) is timely reduced by using sodium hypochlorite and citric acid in an online chemical back - washing system to maintain the stable filtration performance of the membrane. ### Key Results - **COD and BOD5 Removal Efficiencies**: Under different HRTs, the COD removal efficiency of AnMBR exceeds 90%, and the BOD5 removal efficiency exceeds 95%. - **Biogas Production**: The biogas production is basically stable and increases correspondingly as the HRT shortens. Approximately 0.25 to 0.27 liters of biogas can be produced per gram of COD removed, with the methane content continuously exceeding 75% and reaching a maximum of 81%. - **Sludge Production**: The amount of sludge produced per gram of COD removed is approximately 0.19 to 0.26 grams of MLSS. - **Membrane Fouling Control**: The TMP is effectively reduced through an online chemical back - washing system, maintaining the stable filtration performance of the membrane. ### Conclusion This research demonstrates the feasibility and high efficiency of large - scale anaerobic membrane bioreactors in treating actual municipal sewage, especially at an ambient temperature of 25°C. The research results provide detailed practical information for the wide application of AnMBR in municipal sewage treatment in the future.