800.16 Rate of Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement Using the Navitor Valve System Using the Cusp Overlap Technique: A Single-Center Experience

A. Ghoneem,H. Gada,P. Mahoney
DOI: https://doi.org/10.1016/j.jcin.2024.01.241
IF: 11.075
2024-02-28
JACC Cardiovascular Interventions
Abstract:The Navitor valve (Abbott Structural Heart) is the newest self-expanding (SES) transcatheter heart valve (THV) approved for treatment of severe aortic stenosis (AS). While safe & effective, permanent pacemaker implantation (PPI) rates have been reported as high as 15-19%. The cusp overlap technique (COT) for deployment of SES has been associated with low rates of PPI in trials of other THV platforms (OPTIMIZE-PRO). However, it remains unknown if this technique would lead to a lower rate of PPI