Abstract:In this work, a novel levitation magnet with damping coil is proposed to address the existing issues and improve reliability. The fault mechanism of the existing magnet is analyzed and validated using a coupling model combined with inductive voltage experiments. The magnetic yoke with damping coils is designed and the equivalent magnetic circuit (EMC) model of the magnet is established. The nonlinearity of magnetic materials and the magnetic flux fluctuation due to the tooth-slot effect are considered in the EMC model. Simultaneously, the transient finite element (FEM) model is built. The magnetic flux of yoke, the inductive current of the damping coil, and the magnetic force are analyzed. A good agreement is found between EMC and FEM. Additionally, the static magnetic force is tested on the magnet test platform to validate EMC and FEM models. Results reveal that compared with the existing magnet, the magnetic flux fluctuation with damping coils is significantly reduced, and the inductive voltages with the damping coil are significantly decreased. The novel magnet with damping coils featuring excellent magnetic characteristics is more advantageous for the system's security and durability.
environmental sciences,environmental studies,green & sustainable science & technology
What problem does this paper attempt to address?
The problem that this paper attempts to solve is the frequent occurrence of insulation failure of magnetic poles during the long - term operation of high - speed maglev trains. Specifically, the paper analyzes the design flaws of existing magnetic poles and proposes a new maglev magnet design with a damping coil to reduce magnetic flux fluctuations and induced voltages and improve the stability and reliability of the system.
### Problem Background
1. **Maglev Train Technology**:
- Maglev technology is widely used in high - speed machinery, such as maglev flywheels, maglev control moment gyroscopes, and maglev motors.
- High - speed maglev train technology has been studied for a long time worldwide, and several countries have successfully implemented commercial operation projects.
2. **Problems of Existing Magnetic Poles**:
- The magnetic poles of high - speed electromagnetic suspension (EMS) trains often experience insulation failure during long - term operation, resulting in increased maintenance workload and operating costs.
- The voltage at the location where the insulation layer is damaged exceeds the withstand voltage test standard of 2.5 kV, while the maximum power supply voltage of the magnetic pole is only 440 V.
### Problem Analysis
1. **Electromagnetic Coupling Model**:
- An electromagnetic coupling model of a half - magnet was constructed to analyze the causes of magnetic flux fluctuations.
- The main factors include the cogging effect and high - frequency harmonics introduced by the high - frequency chopper power supply, which can cause magnetic flux fluctuations and then generate induced voltages.
2. **Induced Voltage Testing**:
- Ground - equivalent tests and actual vehicle tests were carried out, and the results show that the magnetic poles do generate high - induced voltages exceeding the withstand voltage standard during operation.
- The test results show that the maximum peak - to - peak voltage of magnetic pole 4 in the ground test is 5.5 kV, which is much higher than the withstand voltage standard of 2.5 kV.
### Solution
1. **New Maglev Magnet with Damping Coil**:
- A new maglev magnet with a damping coil was designed to suppress high - frequency magnetic flux fluctuations.
- The damping coil is embedded in the yoke, wound with copper enameled wire, and forms a closed loop in series with a resistor.
- By adjusting the number of turns and resistance value of the damping coil, high - frequency magnetic flux fluctuations can be effectively suppressed without affecting the control of magnetic flux.
### Results and Conclusions
- **Simulation and Experimental Verification**:
- An equivalent magnetic circuit (EMC) model and a transient finite element (FEM) model were established to analyze the magnetic flux, the induced current of the damping coil, and the magnetic force.
- The experimental results show that the new magnet with a damping coil is significantly superior to the existing magnet in terms of magnetic flux fluctuations and induced voltages, improving the safety and durability of the system.
In conclusion, through a detailed analysis of the failure mechanism of existing magnetic poles, this paper proposes a new maglev magnet design with a damping coil, aiming to solve the problem of magnetic pole insulation failure in high - speed maglev trains and improve the reliability and safety of the system.