NIR-Based Electronic Platform for Glucose Monitoring for the Prevention and Control of Diabetes Mellitus

William Oñate,Edwin Ramos-Zurita,Juan-Pablo Pallo,Santiago Manzano,Paulina Ayala,Marcelo V. Garcia
DOI: https://doi.org/10.3390/s24134190
IF: 3.9
2024-06-28
Sensors
Abstract:The glucose level in the blood is measured through invasive methods, causing discomfort in the patient, loss of sensitivity in the area where the sample is obtained, and healing problems. This article deals with the design, implementation, and evaluation of a device with an ESP-WROOM-32D microcontroller with the application of near-infrared photospectroscopy technology that uses a diode array that transmits between 830 nm and 940 nm to measure glucose levels in the blood. In addition, the system provides a webpage for the monitoring and control of diabetes mellitus for each patient; the webpage is hosted on a local Linux server with a MySQL database. The tests are conducted on 120 people with an age range of 35 to 85 years; each person undergoes two sample collections with the traditional method and two with the non-invasive method. The developed device complies with the ranges established by the American Diabetes Association: presenting a measurement error margin of close to 3% in relation to traditional blood glucose measurement devices. The purpose of the study is to design and evaluate a device that uses non-invasive technology to measure blood glucose levels. This involves constructing a non-invasive glucometer prototype that is then evaluated in a group of participants with diabetes.
engineering, electrical & electronic,chemistry, analytical,instruments & instrumentation
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to develop a non - invasive blood - glucose monitoring device to replace the traditional invasive blood - glucose measurement methods. Specifically, the research objective is to design and evaluate an electronic platform using near - infrared spectroscopy (NIR) technology, which can non - invasively measure blood - glucose levels through the skin. This aims to reduce patients' discomfort in traditional blood - glucose monitoring, lower the risk of infection, and improve patients' compliance and quality of life. ### Background of the Paper Diabetes is a chronic disease affecting millions of people worldwide. Regular monitoring of blood - glucose levels is crucial for effectively managing diabetes and preventing complications. Currently, traditional blood - glucose monitoring methods include fingertip blood - sampling tests and continuous blood - glucose monitoring systems (CGM). Although these methods are accurate, they are invasive and may cause pain, discomfort, and the risk of infection, thus affecting patients' compliance and blood - glucose control effectiveness. ### Research Purposes To overcome the above - mentioned problems, researchers have developed a non - invasive blood - glucose monitoring device based on near - infrared spectroscopy (NIR) technology. The main features of this device include: - **Non - invasiveness**: No need for skin puncture, reducing patients' discomfort. - **Accuracy**: Meeting the standards of the American Diabetes Association, with a measurement error within 3%. - **Real - time Monitoring**: Providing a web - page interface for monitoring and controlling the blood - glucose levels of diabetic patients. ### Technical Principles Near - infrared spectroscopy technology utilizes near - infrared light of specific wavelengths to interact with biological tissues and quantitatively analyze blood - glucose concentration by detecting the absorption or scattering of light. The specific steps are as follows: 1. **Signal Acquisition**: Use a near - infrared light source to emit light of specific wavelengths, which enters the interstitial tissue through the skin and then the reflected or transmitted light is collected by the detector. 2. **Signal Processing**: Denoise, amplify, filter, and process the collected electrical signals with mathematical algorithms to extract relevant information. 3. **Data Transmission and Display**: Transmit the processed signals to terminal devices (such as mobile phones) through wireless communication technology and display the results on the web - page interface. ### Experimental Verification Researchers conducted tests on 120 subjects aged between 35 and 85 years old. Each subject had two sample collections using the traditional method and the non - invasive method respectively. The experimental results showed that the measurement error of this device was within 3%, meeting the clinical requirements. ### Conclusions This research has successfully designed and verified a non - invasive blood - glucose monitoring device based on near - infrared spectroscopy technology, providing a painless, convenient, and reliable blood - glucose monitoring solution for diabetic patients. This technology is expected to be widely applied in clinical practice in the future, improving the management and quality of life of diabetic patients.