Expanding the Cell-Free Reporter Protein Toolbox by Employing a Split mNeonGreen System to Reduce Protein Synthesis Workload

Caroline E. Copeland,Chloe J. Heitmeier,Khoa D. Doan,Shea C. Lee,Kassidy B. Porche,Yong-Chan Kwon
DOI: https://doi.org/10.1021/acssynbio.3c00752
IF: 5.249
2024-06-06
ACS Synthetic Biology
Abstract:The cell-free system offers potential advantages in biosensor applications, but its limited time for protein synthesis poses a challenge in creating enough fluorescent signals to detect low limits of the analyte while providing a robust sensing module at the beginning. In this study, we harnessed split versions of fluorescent proteins, particularly split superfolder green fluorescent protein and mNeonGreen, to increase the number of reporter units made before the reaction ceased and enhance the...
biochemical research methods
What problem does this paper attempt to address?
The main problem that this paper attempts to solve is to improve the efficiency and sensitivity of the fluorescent protein reporter system in cell - free systems (CFS). Specifically, the researchers use split fluorescent proteins, especially split super - folding green fluorescent protein (sfGFP) and mNeonGreen (mNG), to reduce the workload of protein synthesis and enhance the signal intensity in the detection of analytes at low concentrations. The main objectives of the paper include: 1. **Reduce the workload of protein synthesis**: By using smaller split fluorescent protein fragments (such as the 11th β - strand of mNeonGreen) instead of complete fluorescent proteins, more reporter units can be generated within a limited protein synthesis time, thereby improving the detection sensitivity. 2. **Improve the limit of detection**: By optimizing the expression and complementation efficiency of the split fluorescent protein system, the cell - free system can generate a stronger fluorescent signal in the presence of analytes at low concentrations, thereby reducing the limit of detection. 3. **Expand the cell - free biosensor toolbox**: By introducing and optimizing the split fluorescent protein system, more options and higher performance are provided for the design of cell - free biosensors. To achieve these goals, the researchers carried out the following key experiments and analyses: - **Compare the complementation efficiencies of different expression systems**: The 1 - 10 and 11th fragments of split sfGFP and mNG were expressed in cell - free systems and whole - cell systems respectively, and their fluorescent signals and complementation efficiencies were compared. - **Optimize the gene concentration ratio**: By adjusting the DNA concentration ratio of the 1 - 10 and 11th fragments, the optimal expression conditions were determined to increase the fluorescent output of the split mNG system. - **Introduce SynZip peptide linkers**: By adding SynZip peptide linkers to the two fragments of split mNG, their complementation efficiency and fluorescent signal intensity were further improved. Overall, through a series of experiments and technical means, this paper successfully improves the performance of the split fluorescent protein reporter system in cell - free systems, providing new methods and tools for the detection of analytes at low concentrations.