A-050 Reference Intervals for Plasma Concentrations of C-Terminal Telopeptide of Type-I Collagen (CTX) for Greek Adult Population

K Makris,I Trifonidi,S Tournis,E Chronopoulos
DOI: https://doi.org/10.1093/clinchem/hvae106.050
IF: 12.114
2024-10-27
Clinical Chemistry
Abstract:BackgroundCTX assays measure a fragment of the C-terminal telopeptide of type I collagen released during resorption of mature bone. To adequately interpret CTX results, method-specific and population specific reference intervals are needed. We aimed to determine reference intervals for plasma concentrations of CTX.MethodsWe collected samples from 431 apparently healthy Greeks (140 men as well as 150 pre- and 139 postmenopausal women), who volunteered to participate in our study. Data on socio-demographic characteristics, medical histories and medications were collected and subjects with conditions or receiving medications that affecting bone metabolism were excluded. Dual-energy x-ray absorptiometry (DXA) used to measure bone mineral density (BMD) in all participants. All blood collections were performed in the morning after overnight fast. Plasma EDTA samples were used for the measurement of CTX. Measurements were performed by an automated chemiluminescent immunoassay on the Maglumi-X3 analyzer (Snibe, Shenzhen, China). The reference interval was defined as the central 95% range and determined according to CLSI guide C28-A3 using the MedCalc Software.ResultsThe table summarizes our results. The mean age of men, pre- and post-menopausal women were 50.7, 40,7 and 58.4 years respectively. DXA results revealed that 348 participants had normal BMD, 74 HAD osteopenia and 9 had osteoporosis which excluded from analysis. Since our data were not normally distributed (Shapiro-Wilk test) in any group and after the exclusion of outliers (Tukey test), we used the non-parametric method suggested by the CLSI guide to determine the reference intervals. Multiple regression analysis also revealed that sex menopausal status and BMD were factors affecting CTX values.ConclusionsWe provide reference intervals for the determination of CTX concentrations in EDTA-plasma for the Greek adult population using an automated immunoassay. Our data may aid to interpret bone turnover in the Greek adult population.
medical laboratory technology
What problem does this paper attempt to address?