Coordinated Reconfiguration with Energy Storage System for Load Restoration in Integrated Electric and Heating Systems

Ke Wang,Jing Wang,Pengfei Su,Song Zhang
DOI: https://doi.org/10.3390/electronics13101931
IF: 2.9
2024-05-16
Electronics
Abstract:Coordinated load restoration of integrated electric and heating systems (IEHSs) has become indispensable following natural disasters due to the increasingly relevant integration between power distribution systems (PDS) and district heating systems (DHS). In this paper, a coordinated reconfiguration with an energy storage system is introduced to optimize load restoration in the aftermath of natural catastrophes. By modifying the DHS network topology, it is possible to maintain an uninterrupted energy supply in unfaulty zones by shifting heat loads among sources and adjusting the operation of coupled devices. Additionally, energy storage systems with rapid response times are implemented to enhance load restoration efficiency, especially when working in conjunction with multiple energy sources. Comprehensive case analyses have been systematically conducted to demonstrate the impact of coordinated reconfiguration with energy storage systems on improving load restoration.
engineering, electrical & electronic,computer science, information systems,physics, applied
What problem does this paper attempt to address?
This paper attempts to solve the problem of power and heat load recovery in integrated electricity and heating systems (IEHSs) after natural disasters. Specifically, the paper focuses on the following aspects: 1. **Fault Isolation and Recovery**: - **Fault Isolation Phase**: Through the joint operation of the power distribution system (PDS) and the district heating system (DHS), accurately locate the faulty nodes or buses in the network, and clarify the boundaries between the faulty area and the non - faulty area, so as to effectively manage the spread range of faults. - **Recovery Phase**: After fault isolation, through the coordinated re - configuration of the PDS and DHS, quickly and efficiently restore services in the unaffected areas, reducing downtime and the impact on end - users. 2. **Application of Energy Storage Systems**: - **Fast Response Capability**: Utilize the fast - response characteristics of the energy storage system (ESS) to ensure the continuous power supply of critical loads. Especially with the cooperation of multiple energy sources, it can quickly restore important loads and ensure that critical services continue to operate during the recovery period. - **Multi - Energy Source Integration**: By integrating multiple energy sources, the ESS can flexibly switch between different energy sources, improving the resilience and flexibility of the system and reducing the impact of disasters on communities and the economy. 3. **Coordinated Recovery Strategies**: - **Network Topology Adjustment**: By modifying the DHS network topology, an uninterrupted energy supply can be maintained in the unaffected areas, which is achieved by transferring heat loads between different heat sources and adjusting the operation of coupling devices. - **Optimization of CHP Units**: Combined with PDS switching operations, adjust the operating output of CHP units to optimize the recovery of electricity and heat energy, shorten the power outage time, and improve the ability to respond to emergencies. 4. **Models and Constraints**: - **Network Topology Constraints**: Define the network structure constraints in the fault isolation and recovery processes to ensure the effective isolation and recovery of the faulty area and the non - faulty area. - **Operation Constraints**: Include constraints in multiple aspects such as power balance, transmission capacity, voltage drop, unit power generation, load shedding, and ESS operation to ensure the stable operation of the system during the recovery process. 5. **Objectives and Resilience Indicators**: - **Minimize Load Loss**: Through the optimization model, minimize the loss of electrical and thermal loads during the fault recovery process. - **Evaluate the Recovery Level**: Evaluate the recovery effect of the proposed strategy through resilience indicators and quantify the degree of load recovery. In summary, this paper aims to improve the load recovery ability and system resilience of the integrated electricity and heating system after natural disasters through the coordinated re - configuration of the PDS and DHS and the application of the ESS.