Abstract:In grid-connected photovoltaic (PV) systems, power quality and voltage control are necessary, particularly under unbalanced grid conditions. These conditions frequently lead to double-line frequency power oscillations, which worsen Direct Current (DC)-link voltage ripples and stress DC-link capacitors. The well-known dq frame vector control technique, which is effective under normal conditions, struggles with oscillatory component management in unbalanced grid conditions. To address this issue, this paper presents an advanced control approach designed for grid-connected PV inverters. The proposed approach is effective at reducing oscillations in the DC-link voltage at double the grid frequency, thereby enhancing system stability and component longevity. This method introduces a feedback control method designed to regulate oscillatory components that appeared within the dq frame and suppress the DC-link voltage oscillations under imbalance conditions, including single line-to-ground (SLG) faults. Additionally, the control scheme incorporates a maximum power point tracking (MPPT) controller to optimize PV efficiency. Comprehensive simulations demonstrate the effectiveness of this method in maintaining sinusoidal current injections and stabilizing DC-link voltage during unbalanced grid conditions. Simulation results show that the control scheme effectively stabilizes DC-link voltage, maintains balanced grid current, and ensures constant active power under various conditions, including SLG faults and solar irradiance changes.
engineering, chemical
What problem does this paper attempt to address?
### Problems the paper attempts to solve This paper aims to solve the problems faced by photovoltaic (PV) inverters connected to the power grid under unbalanced grid conditions. Specifically, the paper focuses on the following key issues: 1. **Power quality and voltage control under unbalanced grid conditions**: - Under unbalanced grid conditions, double - line - frequency power oscillations (i.e., oscillations with a frequency twice that of the grid fundamental frequency) will lead to intensified DC - link voltage fluctuations, thereby increasing the stress on the DC - link capacitor and shortening its lifespan. - Although the common dq - coordinate - system vector control techniques work well under normal conditions, they are difficult to effectively manage the oscillatory components under unbalanced grid conditions. 2. **Reducing DC - link voltage fluctuations**: - An advanced control method is proposed, aiming to reduce the oscillations of the DC - link voltage at twice the grid fundamental frequency, thereby improving the system stability and the lifespan of components. - This method introduces a feedback control strategy for regulating the oscillatory components in the dq - coordinate system and suppressing DC - link voltage fluctuations. 3. **Optimizing maximum power point tracking (MPPT)**: - An MPPT controller based on the perturbation and observation method (P&O) is integrated into the control scheme to optimize the efficiency of the PV array. 4. **Maintaining sinusoidal current injection and system stability**: - The effectiveness of this method has been verified by simulation. It can maintain sinusoidal current injection under unbalanced grid conditions, stabilize the DC - link voltage, and ensure a constant active power output. ### Formula summary 1. **dq transformation**: - Representation of three - phase grid voltages and currents in the dq - coordinate system: \[ \begin{bmatrix} v_{d,\text{dc}} \\ v_{d,\text{ac}} \\ v_{q,\text{dc}} \\ v_{q,\text{ac}} \end{bmatrix} = \frac{1}{3} \begin{bmatrix} 1 & 1 & 1 \\ -\cos(2\theta_a) & -\cos(2\theta_b) & -\cos(2\theta_c) \\ 0 & 0 & 0 \\ \sin(2\theta_a) & \sin(2\theta_b) & \sin(2\theta_c) \end{bmatrix} \begin{bmatrix} \hat{v}_a \\ \hat{v}_b \\ \hat{v}_c \end{bmatrix} \] \[ \begin{bmatrix} i_{d,\text{dc}} \\ i_{d,\text{ac}} \\ i_{q,\text{dc}} \\ i_{q,\text{ac}} \end{bmatrix} = \frac{1}{3} \begin{bmatrix} \cos(\alpha) & \cos(\alpha) & \cos(\alpha) \\ \cos(2\theta_a + \alpha) & \cos(2\theta_b + \alpha) & \cos(2\theta_c + \alpha) \\ \sin(\alpha) & \sin(\alpha) & \sin(\alpha) \\ \sin(2\theta_a + \alpha) & \sin(2\theta_b + \alpha) & \sin(2\theta_c + \alpha) \end{bmatrix} \begin{bmatrix} \hat{I}_a \\