Near-field Terahertz Sensing of HeLa Cells and Pseudomonas Based on Monolithic Integrated Metamaterials with a Spintronic Terahertz Emitter
Zhongyang Bai,Yongshan Liu,Ruru Kong,Tianxiao Nie,Yun Sun,Helin Li,Tong Sun,Chandan Pandey,Yining Wang,Haoyi Zhang,Qinglin Song,Guozhen Liu,Michael Kraft,Weisheng Zhao,Xiaojun Wu,Lianggong Wen
DOI: https://doi.org/10.1021/acsami.0c08543
2020-07-09
Abstract:Label-free biosensors operating within the terahertz (THz) spectra have helped to unlock a myriad of potential THz applications, ranging from biomaterial detection to point-of-care diagnostics. However, the THz wave diffraction limit and the lack of emitter-integrated THz biosensors hinder the proliferation of high-resolution near-field label-free THz biosensing. Here, a monolithic THz emission biosensor (TEB) is achieved for the first time by integrating asymmetric double-split ring resonator metamaterials with a ferromagnetic heterojunction spintronic THz emitter. This device exhibits an electromagnetically induced transparency window with a resonance frequency of 1.02 THz and a spintronic THz radiation source with a bandwidth of 900 GHz, which are integrated on a fused silica substrate monolithically for the first time. It was observed that the resonance frequency experienced a red-shift behavior with increasing concentration of HeLa cells and <i>Pseudomonas</i> because of the strong interaction between the spintronic THz radiation and the biological samples on the metamaterials. The spatial frequency red-shift resolution is ∼0.01 THz with a Pseudomonas concentration increase from ∼0.5 × 10<sup>4</sup> to ∼1 × 10<sup>4</sup>/mL. The monolithic THz biosensor is also sensitive to the sample concentration distribution with a 15.68 sensitivity under a spatial resolution of 500 μm, which is determined by the infrared pump light diffraction limit. This TEB shows great potential for high-resolution near-field biosensing applications of trace biological samples.The Supporting Information is available free of charge at <a class="ext-link" href="/doi/10.1021/acsami.0c08543?goto=supporting-info">https://pubs.acs.org/doi/10.1021/acsami.0c08543</a>.Comparison of structural and sensitivity performance of other purposed biosensors and the ones in this work (<a class="ext-link" href="/doi/suppl/10.1021/acsami.0c08543/suppl_file/am0c08543_si_001.pdf">PDF</a>)This article has not yet been cited by other publications.
materials science, multidisciplinary,nanoscience & nanotechnology