High-sensitive sensor for the simultaneous determination of phenolics based on multi-walled carbon nanotube/NiCoAl hydrotalcite electrode material

Zhen Li,Hong-Yan Zeng,Xiao-Ju Cao,Hao-Bo Li,Yi-Wen Long,Bo Feng,Shi-Bing Lv
DOI: https://doi.org/10.1007/s00604-021-04948-1
IF: 5.7
2021-08-27
Microchimica Acta
Abstract:The ternary NiCoAl hydrotalcite (NiCoAl-LDH) was combined with carboxylic multi-walled carbon nanotube (MWCNT) to fabricate a novel electrochemical sensor for simultaneously determining the co-existing trace phenolic substances. The morphology, structure, and electrochemical behavior of the as-prepared materials were characterized by various techniques. Benefitting from the great conductivity of MWCNT and high electrocatalytic activity of NiCoAl-LDH for phenolic substances, the advanced MWCNT/NiCoAl-LDH sensor presented a fast response, high sensitivity, excellent stability, and satisfactory replicability. The sensor offered good linear responses in the ranges1.50~600 μM to hydroquinone (HQ), 5.00~1.03 × 103 μM to catechol (CC), and 6.00 × 10−2~250 μM to bisphenol A (BPA). The detection limits of HQ, CC, and BPA were 0.4, 0.8, and 6. × 10−3 μM (S/N = 3), respectively. In environmental water, the sensor achieved satisfactory recoveries for the simultaneous detection of HQ (98.6~101%), CC (98.0~101%), and BPA (97.5~101%), with relative standard deviations less than 4.4%.
chemistry, analytical
What problem does this paper attempt to address?