Distinct Diurnal Cycle of Supercooled Water Cloud Fraction Dominated by Dust Extinction Coefficient
Yang Wang,Jiming Li,Yuxin Zhao,Yarong Li,Yang Zhao,Xiaolin Wu
DOI: https://doi.org/10.1029/2021gl097006
IF: 5.2
2022-01-21
Geophysical Research Letters
Abstract:Cloud phase (CP) partitioning (e.g., supercooled water cloud fraction, SCF) is often misrepresented in model simulations. One of the remarkable uncertainties involves the poor understanding of SCF diurnal cycle due to lack of observations. By using 33 months of lidar observations from Cloud‐Aerosol Transport System which provides cloud top phase at different local times for a given grid and isotherm, this study first characterizes the diurnal cycle of SCF between 51°S and 51°N. Distinct SCF diurnal variations have been found near‐global at different isotherms, especially for −22.5°C, where SCF diurnal ranges even reach 60%. Correlation analysis shows a robust dependence of SCF diurnal cycle on the variation of dust aerosol extinction coefficient instead of other dust load indicators and meteorological parameters. Given the important roles of SCF on the radiation budget, this study will help us better constrain aerosol‐cloud interaction and simulations of CP partitioning in models. Clouds in nature are comprised of liquid droplets, ice crystals or a mixture of the two (i.e., mixed‐phase) at temperatures between −40°C and 0°C. Clouds with different cloud phases (CPs) exhibit distinct radiative effect due to differences of cloud liquid and ice in refractive indices, sizes, concentrations and shapes. However, CP partitioning (e.g., supercooled water cloud fraction, SCF) is still misrepresented in model simulations. One crucial reason is the lack of observations and understanding of SCF diurnal variations. This study first characterizes the SCF diurnal variations by using ∼33 months of lidar observations from Cloud‐Aerosol Transport System which provides cloud top phase at different daily times for a given grid and isotherm. Distinct SCF cycle has been found globally at different isothermal layers with a minimum (maximum) SCF around midday (midnight), which is mainly related with the diurnal cycle of dust aerosols extinction coefficient (EC). Given the important roles of SCF on the radiation budget, this work suggests that EC may be considered as the robust dust load indicator to study aerosol‐cloud interaction and further improve the simulations of CP partitioning in climate models. Distinct supercooled water cloud fraction (SCF) diurnal variations have been found near‐global at different isothermal layers The SCF reaches a minimum (maximum) around midday (midnight) Compared with other parameters, the dust extinction coefficient is highly correlated with SCF diurnal cycle Distinct supercooled water cloud fraction (SCF) diurnal variations have been found near‐global at different isothermal layers The SCF reaches a minimum (maximum) around midday (midnight) Compared with other parameters, the dust extinction coefficient is highly correlated with SCF diurnal cycle
geosciences, multidisciplinary
What problem does this paper attempt to address?