Experimental investigation on hydrogen transfer in coupled metal hydride reactors for multistage hydrogen purification application

Alok Kumar,P. Muthukumar
DOI: https://doi.org/10.1016/j.apenergy.2024.123076
IF: 11.2
2024-03-31
Applied Energy
Abstract:Three stage metal hydride hydrogen separation system was tested, wherein each stage was configured with 1.2 kg of LaNi 4.7 Al 0.3 , LaNi 5 and La 0.9 Ce 0.1 Ni 5 , placed in descending order of their equilibrium bed pressure respectively as R1 (La 0.9 Ce 0.1 Ni 5 ) > R2 (LaNi 5 ) > R3 (LaNi 4.7 Al 0.3 ). Hydrogen absorption capacity obtained for R1, R2 and R3 were 15.91 g, 15.93 g and 16.02 g respectively for 3 rd activation cycle, performed at 30 bar and 25 °C. For coupled reactor operation, optimum hydrogen transfer was for desorbing reactor at 90 °C and absorbing reactor at 20 °C, which was 12.31 g for R1 to R2 in 350 s, 13.33 g for R2 to R3 in 300 s and 13.38 g for R1 to R2 in 280 s, constituting to 1.03, 1.11 and 1.12 wt% of hydrogen storage respectively. Further, the system was tested for hydrogen purification, wherein inlet sample with 80% impurity (18% Ar, 20% CO 2 , 20% N 2 , 20% CH 4 and 2% CO) and 20% H 2 was used for purification study. According to Thermal Conductivity Detector (TCD) results, the system delivered 91.54%, 99.996% and 99.9999% pure hydrogen respectively for stage 1, stage 2 and stage 3 purification. The system works within low temperature range of 20–90 °C.
energy & fuels,engineering, chemical
What problem does this paper attempt to address?