Boron carbide biodevices for disease-specific biomarker detection: a theoretical study
Ahmed Mahal Abdulrahman T. Ahmed Subhash Chandra Maan Muwaffaq Nayef Hasan Khalid Dabis Ahmad J. Obaidullah Saeb Jasim Al-Shuwaili Ahmed Muzahem Al-Ani Rahadian Zainul a Department of Medical Biochemical Analysis,College of Health Technology,Cihan University-Erbil,Erbil,Kurdistan Region,Iraqb Department of Nursing,Al-Maarif University College,AL-Anbar Governorate,Ramadi,Iraqc Department of Electrical Engineering,GLA University,Mathura,281406,Indiad Department of Dentistry,Al-Noor University College,Nineveh,Iraqe Ahl Al Bayt University,Kerbala,Iraqf Department of Pharmaceutical Chemistry,College of Pharmacy,King Saud University,Riyadh,P. O. Box 2457,Saudi Arabiag Department of Anesthesia Techniques,Al-Hadi University College,Baghdad,10011,Iraqh Department of Medical Engineering,Al-Nisour University College,Baghdad,Iraqi Department of Chemistry,Faculty of Mathematics and Natural Sciences,Universitas Negeri Padang,Sumatera Barat,Indonesiaj Center for Advanced Material Processing,Artificial Intelligence,and Biophysics Informatics (CAMPBIOTICS),Universitas Negeri Padang,Padang,Indonesiak Research Fellow,INTI International University,Nilai,Negeri Sembilan,71800,Malaysial Professor Fellow,Superior University,Lahore,Pakistan
DOI: https://doi.org/10.1080/00958972.2024.2423850
2024-11-09
Journal of Coordination Chemistry
Abstract:An effective approach for early diagnosis of lung cancer involves detecting its biomarkers in the patient's exhaled breath. Acetone was identified as a vital biomarker, showing significant elevation in lung cancer. Two-dimensional boron carbide materials offer benefits such as resistance to high temperatures, stability, and excellent sensitivity toward toxic gas molecules. Here, we explore acetone adsorption on the pristine and transition metal (TM)-doped (Sc, Ti, V, Cr, and Mn) boron carbide monolayers (BCMs) with density functional theory calculations. Our results revealed that the V-, Cr-, and Mn-doped BCM show larger adsorption energy values as compared to the pristine BCM surface. The change of band gap energy of surfaces after acetone adsorption is obtained between 55 and 275%. The work function variation of studied monolayers upon acetone adsorption has been also investigated and results show that V-, Cr-, and Mn-doped BCM systems are sensitive to acetone gas molecules. This work suggests that BCM-based layers can be used as a biosensor to identify VOC biomarkers such as acetone.
chemistry, inorganic & nuclear