Electro‐Oxidation of Ibuprofen and Metoprolol Using a Manganese Oxide Platform

Pheladi Lizzy Mokaba,Titus A. M. Msagati,Hlengilizwe Nyoni,Bhekie B. Mamba,Usisipho Feleni
DOI: https://doi.org/10.1002/slct.202400385
2024-10-10
ChemistrySelect
Abstract:This work involves the development of an electrochemical sensor using a screen‐printed carbon electrode (SPCE) modified with a manganese oxide platform for the detection of ibuprofen and metoprolol in wastewater. The modified SPCE leverages the electro‐oxidation properties of manganese oxide to enhance the sensitivity and selectivity of the sensor. The research focuses on optimizing the electrode modification process, characterizing the sensor's performance, and applying it to real wastewater samples to detect and quantify the presence of these pharmaceutical contaminants. This study aims to provide a reliable and efficient method for environmental monitoring and pollution control. Pharmaceutical compounds, such as ibuprofen and metoprolol, are of increasing concern due to their persistence in the environment and potential adverse effects on human health. In this work, we developed an electrochemical sensor system for the determination of ibuprofen and metoprolol based on a modified manganese oxide nanoparticle (MnO2NPs) on a screen‐printed carbon electrode (SPCE). The characterisation of MnO2NPs modifier was investigated via Fourier transform infrared (FTIR), X‐ray diffraction (XRD), scanning electron microscopy (SEM), Raman spectroscopy techniques, Uv/vis spectroscopy, and small‐angle X‐ray scattering spectroscopy. The electrochemical behaviour of the MnO2NPs was studied using differential pulse voltammetry (DPV) and cyclic voltammetry (CV) techniques. The optimum experimental conditions were investigated by examining the effects of scan rates, pH on the CV responses, and electrolytes on the DPV response. The MnO2NPs modified electrode demonstrated enhanced catalytic activity in the electro‐oxidation of both ibuprofen and metoprolol. The oxidation peaks of ibuprofen and metoprolol were observed at +1.14 V and +1.46 V, respectively, for the MnO2NPs/SPCE sensor. The sensor's limit of detection was 3.81 pM and 4.6 pM respectively and its linear response was from 0.97–5.82 pM. Furthermore, interference and stability studies were conducted to evaluate the performance of the MnO2NPs/SPCE sensor under optimum conditions, which resulted in a good performance. The proposed sensor was successfully used for the determination of ibuprofen and metoprolol in the application of real water samples.
chemistry, multidisciplinary
What problem does this paper attempt to address?