Insight into the Contact Impedance between the Electrode and the Skin Surface for Electrophysical Recordings

Liangtao Yang,Lu Gan,Zhenggang Zhang,Zhilin Zhang,Hui Yang,Yi Zhang,Jinglong Wu
DOI: https://doi.org/10.1021/acsomega.2c00282
IF: 4.1
2022-04-14
ACS Omega
Abstract:To obtain a performance improved dry electrode for bioelectrical activity detection is still a challenge, which is mainly due to the poor fundamental understanding on the impedance of the electrode-skin interface. Herein, the impedance between the electrode and the skin interface of three types of electrodes, which are the wet electrode, semidry electrode, and dry electrode, is investigated with electrochemical impedance spectroscopy combined with the spectra fitting technique. The parameters of performance duration, potential, and frequency associated with the impedance are explored for these three types of electrodes. The overall impedance is roughly constant within the performance duration and the potential applied in this study. Along with the frequency decreases, the impedance of the dry electrode reduces faster and is more complicated compared with the other two types of electrodes. Moreover, the results computed with the equivalent circuits show that the charge transfer resistance is additionally present compared to the wet and semidry electrodes. This large and additional charge transfer resistance may explain its relatively poorer electrophysiological properties.
chemistry, multidisciplinary
What problem does this paper attempt to address?
The problem that this paper attempts to solve is: **Improve the performance of dry electrodes for bio - electrical signal detection, especially by in - depth understanding of the impedance characteristics between the electrode and the skin interface**. Specifically, the researchers noted that although dry electrodes have advantages in terms of ease of use and comfort, their performance is still inferior to that of wet electrodes and semi - dry electrodes in practical applications. The main reason is the lack of in - depth understanding of the electrode - skin interface impedance. In order to improve the performance of dry electrodes, it is necessary to have an in - depth understanding of the impedance characteristics and their influencing factors when different types of electrodes (wet electrodes, semi - dry electrodes, and dry electrodes) are in contact with the skin. ### Main problems 1. **Influencing factors of electrode - skin interface impedance**: The researchers hope to explore the impedance changes of different types of electrodes (wet electrodes, semi - dry electrodes, and dry electrodes) under different conditions through electrochemical impedance spectroscopy (EIS) combined with spectral fitting techniques. 2. **Reasons for the poor performance of dry electrodes**: By comparing the impedance characteristics of the three types of electrodes, the researchers hope to find the specific reasons for the poor performance of dry electrodes, especially whether there are additional resistances (such as charge - transfer resistance) that cause their performance to decline. 3. **Optimizing dry electrode design**: Based on an in - depth understanding of the electrode - skin interface impedance, the researchers hope to be able to provide a theoretical basis for improving the design of dry electrodes, thereby improving their performance in bio - electrical signal detection. ### Research methods - **Experimental objects**: Rat skin and human arm skin. - **Experimental equipment**: Three - electrode system, including working electrodes (wet electrodes, semi - dry electrodes, dry electrodes), counter electrodes, and reference electrodes. - **Measured parameters**: Potential range, performance duration, frequency, etc. - **Analysis methods**: Electrochemical impedance spectroscopy and equivalent circuit fitting. ### Key findings - **The impedance of wet electrodes and semi - dry electrodes is low**, especially on rat skin, the impedance of wet electrodes is the lowest; while on the human arm, the impedance of semi - dry electrodes is the lowest. - **The impedance of dry electrodes is significantly higher than that of the other two types of electrodes**, especially under low - frequency conditions, the impedance of dry electrodes changes more, and there is an additional charge - transfer resistance. - **Equivalent circuit analysis** shows that the charge - transfer resistance of dry electrodes is large, which may be the main reason for their poor performance. ### Conclusion By in - depth studying the impedance characteristics of the electrode - skin interface, the researchers revealed the reasons for the poor performance of dry electrodes and provided an important theoretical basis for optimizing dry electrode design in the future. This will help to develop dry electrodes with better performance and further promote the development of bio - electrical signal detection technology.