Preliminary Analysis of Passive Residual Heat Removal System for a Nuclear-powered Ship
Y. Jeong,W. Park
Abstract:Recently, a major focus in the nuclear field lies on developing small and medium sized reactors (SMRs). Their purpose is not only restricted to electricity generation but also non-electric applications such as propulsion or desalination. In particular, nuclear propulsion has received considerable attention to date. One of the main reason is that high power source has become important for ships. For examples, in cases of icebreaker or commercial large cargo ship, around 100 MWth ~ 200 MWth of output is required, which is a typical value of that of SMRs. In addition, International Maritime Organization (IMO) requests the reduction of the greenhouse gas emission recently. In line with those trends, the nuclear marine propulsion has gained interest. In order for the nuclear marine propulsion to be widely applied, safety of the system must be assured. Especially, the ocean condition restricts the outside intervention for mitigating accident cases, which implies that passive safety is essential. Among many passive safety systems, a passive residual heat removal system (PRHRS) is of interest in this study. In the land-based PRHRS, one of the most practical and fully-passive configuration is the system where the initial large decay heat is removed by outside pre-installed water tank, and after all the water evaporates air-cooling tower cools down the heat. This system can effectively remove the decay heat for a longterm without relying on any intervention, but it usually requires a large volume of the air-cooling tower. In the ocean-based PRHRS, the available space for the reactor system is very limited, meaning that the conventional large one is not suitable for this case. Therefore, a new concept of PRHRS, which combines the air-cooled tower and the seawater-cooling is suggested. The basic idea is as follows. Some amount of decay heat is removed by the air-cooled tower, which is installed at the upper part, inducing the natural circulation flow. Then the seawater-cooling part effectively removes the rest of decay heat as temperature of the seawater is very low, although the flow rate is small. That is, the required size of the air-cooled tower is expected to be decreased because the seawater can reduce the heat removal load of the tower. However, the system characteristic will be different from that of conventional one, since two heat sinks are installed in a single loop. Therefore, the purpose of this study is preliminary designing the system and evaluating the overall size of it. The results can provide a first insight into the new concept of system. This paper describes the characteristic of buoyancy head of the system, air-cooled condenser design, and feasibility of the system.
Physics,Engineering,Environmental Science