Composite Slab Behavior and Strength Analysis. Part II: Comparisons with Test Results and Parametric Analysis
Byron J. Daniels,Michel Crisinel
DOI: https://doi.org/10.1061/(asce)0733-9445(1993)119:1(36)
1993-01-01
Journal of Structural Engineering
Abstract:The results of selected tests on fullscale oneway single and continuous span composite slabs with ribbed decking are presented. Variables investigated in these tests include the number of spans, the presence of embossments in the decking, end anchorage (both welded and shotfired shear connectors), and negative moment reinforcement near interior supports. An example comparison is given between a standard test and the calculation procedure combining shearbond test results with a finite element analysis (the calculation procedure was presented in part I). The importance of composite slab internal moment resistances as a function of the applied load is examined. For a composite slab, three internal moment resistance elements are of importance: the decking, concrete slab (including additional reinforcement), and the interaction between decking and concrete slab. Parametric analyses based upon the calculation procedure predictions are performed for three decking geometries using limiting slenderness ratios. Decking types were chosen to represent a wide range of shear bond connection characteristics. Slenderness ratio is defined as the span length divided by the total composite slab depth. The effects of eleven parameters are investigated for each decking and slenderness. Effects studied include the loadcarrying capacity at service deflection limits (L/250), ultimate deflection limits (L/50), and maximum loadcarrying capacity.
construction & building technology,engineering, civil