Dilution dysfunction: evaluation of automated disinfectant dispenser systems in 10 hospitals demonstrates a need for improved monitoring to ensure that correct disinfectant concentrations are delivered

Jennifer L. Cadnum,Claire E. Kaple,Elizabeth C. Eckstein,Elie A. Saade,Amy J. Ray,Trina F. Zabarsky,Bernardino J. Guerrero,Mohamed H. Yassin,Curtis J. Donskey
DOI: https://doi.org/10.1017/ice.2024.148
2024-10-12
Infection Control and Hospital Epidemiology
Abstract:Automated dispensers that dilute concentrated disinfectants with water are commonly used in healthcare facilities. In a point-prevalence product evaluation, 9 of 10 (90%) hospitals using dilutable disinfectants had 1 or more malfunctioning dispensers. Twenty-nine of 107 (27.1%) systems dispensed product with lower-than-expected concentrations, including 15 (14.0%) with no detectable disinfectant.
infectious diseases,public, environmental & occupational health
What problem does this paper attempt to address?