Abstract:The 100-m X-ray Test Facility (100XF) was developed according to the calibration requirement of the first X-ray astronomical satellite Insight -HXMT in china. After that, the 100XF has provided calibration services for other X-ray astronomical satellites. In order to test the energy response matrices of space-borne detectors and to extend the capability of 100XF, a monochromator based on channel-cut crystals is developed. So far, 3.0-20.7 keV monochromatic X-rays have been realized successfully with Si(111) crystal. The monochromaticity ( /E) is better than 0.6% @5.9 keV, the flux stability can reach 2.6% in about one hour. The energy stability is particularly good, the variation is 0.05% in about one hour. Further more, the beam spot spreads in the plane orthogonal to the rocking direction after a propagation of 100-meter, which is sufficient and useful for testing detectors with large sensitive area. In this paper, we present the research and establishment of the X-ray monochromator at the 100XF.
astronomy & astrophysics
What problem does this paper attempt to address?
The paper mainly addresses the following issues: 1. **Development of X-ray Monochromator**: To test the energy response matrix of space detectors and extend the capabilities of the 100-meter X-ray testing facility (100XF), the research team designed and established an X-ray monochromator based on channel-cut crystals. 2. **Achieving Monochromatic X-rays in Specific Energy Range**: By adjusting the Bragg angle, monochromatic X-rays in the energy range of 3.0 to 20.7 kilo-electron volts (keV) were successfully achieved. At 5.9 keV, the monochromaticity (ΔE_FWHM/E) was better than 0.6%. 3. **Enhancing Calibration Capability**: This monochromator can provide high-quality monochromatic X-ray beams, which are crucial for calibrating the energy response matrix of space-borne detectors, helping to obtain reliable observational data. 4. **Meeting Various Needs**: The high purity, stability, and medium-area beam coverage characteristics of the monochromatic X-rays make them suitable for testing detectors with larger sensitive areas. 5. **Performance Evaluation**: Key parameters such as the spatial distribution, energy range, purity, monochromaticity, and stability of the monochromatic X-ray beam were thoroughly tested, proving that the monochromator's performance meets the requirements. 6. **Application Prospects**: This monochromator can support the calibration work of existing astronomical satellites and provide support for future astronomical missions, such as the enhanced X-ray Timing and Polarimetry mission (eXTP). In summary, this paper addresses the issue of how to produce high-quality monochromatic X-rays to support the calibration of space detectors by designing and implementing an X-ray monochromator based on channel-cut crystals, and demonstrates its good performance in practical applications.