(99m)Tc-antigranulocyte antibody scintiscan versus computed tomography and ultrasound in the detection of silent mesh infection of the abdominal wall.
M. Žuvela,A. Antić,M. Petrović,M. Kerkez,A. Milovanović,V. Obradović
2011-05-01
Hellenic journal of nuclear medicine
Abstract:To the Editor: Incisional hernias as a defect of abdominal wall on the site of previous laparotomy incision occur in 10% [1]. Up to now, the best results of the incisional hernia treatment have been achieved by non-resorbable mesh hernia repair [2]. Late mesh infections are common complications [3], resistant to conservative treatment which seldom require partial, or more frequently complete removal of the mesh along with residual defect after various sometime multi-staged procedures [4]. Diagnosis of mesh infection is usually set up by clinical examination, and confirmed by ultrasonography (US), computerized tomography (CT) or bacteriology tests. «Silent» mesh infections develope in one half of the patients and can be a diagnostic problem for US, CT and other imaging techniques [3]. Ultrasound and CT can not sometimes differentiate between inflammation and infection in the course of the postoperative healing process and are not of great help in the early stage of the disease when there are still no anatomic changes [5]. In cases where there were no typical clinical signs of mesh infection, we performed scintigraphy using technetium-99m antigranulocyte antibodies (99mTc-Agc Ab) and compared its diagnostic significance with US and CT [6-9]. Ultrasonography was done with 5to 10-MHz linear-array transducer (Diagnostic Ultrasound System SDU-2200, Shimadzu, Japan) in supine position of the patient with relaxed and contracted abdominal muscles. Computed tomography of the abdomen was performed using a single-slice spiral CT (SCT 7800 TC Shimatzu, Japan), with a slice thickness of 5mm, or 7mm, after i.v. injection of iodinated contrast by an automatic injector, in the portal-venous phase (80-100mL of the iodinated contrast 300mg I/mL, flow 3mL/s, scanning delay: 50s). Scintimun granulocyte (murine monoclonal antibody, clone 250/183-MoAb BW 250/183), was used, labelled with 99mTcpertechnetate. Thin layer chromatography was used for radiochemical purity test. Acquisition was performed using Siemens ECAT scintillation camera after slow i.v. injection of 370MBq 99mTc labelled monoclonal antibodies BW 250/183 in the cubital vein. Whole body scintigrams (16cm/min) were obtained in anterior and posterior positions 4h after application of the radiopharmaceutical. After initial qualitative analysis, semi-quantitative one followed. After assessment of the increased accumulation of the radiopharmaceutical in the selected area, target-background (T/B) ratio (i.e. the ratio between the area of interest and a similar contralateral abdominal area) was calculated. Our patient was a 65 years male with right reccurent subcostal incisional hernia without clinical signs of infection as a result of several previous operations, which had as complications wound infection, right subcostal hernia, mesh infection and recurrent incisional hernia (Fig. 1). The 99mTc-Agc Ab scintigraphy showed a deep mesh infection of the the abdominal wall, in the region of the scar of previous operations; while US and CT indicated no infection (Fig. 2 and 3). Target-background ratio in the anterior scintigram was 3.2. Mesh repair, although followed by good early and late results in comparison to hernia recurrence, always bears the risk of a foreign body infection. Nonresorbable mesh should by no means be used in the presence of abdominal wall defect infection. Components separation technique could be used in contaminated wound conditions providing excellent early results, but with uncertain outcome regarding recurrence.