Patient's Healthy-Limb Motion Characteristic-Based Assist-As-Needed Control Strategy for Upper-Limb Rehabilitation Robots

Bingjing Guo,Zhenzhu Li,Mingxiang Huang,Xiangpan Li,Jianhai Han
DOI: https://doi.org/10.3390/s24072082
IF: 3.9
2024-03-26
Sensors
Abstract:The implementation of a progressive rehabilitation training model to promote patients' motivation efforts can greatly restore damaged central nervous system function in patients. Patients' active engagement can be effectively stimulated by assist-as-needed (AAN) robot rehabilitation training. However, its application in robotic therapy has been hindered by a simple determination method of robot-assisted torque which focuses on the evaluation of only the affected limb's movement ability. Moreover, the expected effect of assistance depends on the designer and deviates from the patient's expectations, and its applicability to different patients is deficient. In this study, we propose a control method with personalized treatment features based on the idea of estimating and mapping the stiffness of the patient's healthy limb. This control method comprises an interactive control module in the task-oriented space based on the quantitative evaluation of motion needs and an inner-loop position control module for the pneumatic swing cylinder in the joint space. An upper-limb endpoint stiffness estimation model was constructed, and a parameter identification algorithm was designed. The upper limb endpoint stiffness which characterizes the patient's ability to complete training movements was obtained by collecting surface electromyographic (sEMG) signals and human–robot interaction forces during patient movement. Then, the motor needs of the affected limb when completing the same movement were quantified based on the performance of the healthy limb. A stiffness-mapping algorithm was designed to dynamically adjust the rehabilitation training trajectory and auxiliary force of the robot based on the actual movement ability of the affected limb, achieving AAN control. Experimental studies were conducted on a self-developed pneumatic upper limb rehabilitation robot, and the results showed that the proposed AAN control method could effectively estimate the patient's movement needs and achieve progressive rehabilitation training. This rehabilitation training robot that simulates the movement characteristics of the patient's healthy limb drives the affected limb, making the intensity of the rehabilitation training task more in line with the patient's pre-morbid limb-use habits and also beneficial for the consistency of bilateral limb movements.
engineering, electrical & electronic,chemistry, analytical,instruments & instrumentation
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to implement an "as - needed assistance" (AAN) control strategy based on the movement characteristics of the patient's healthy limb in the upper - limb rehabilitation robot. Traditional AAN control methods mainly rely on evaluating the movement ability of the patient's impaired limb to determine the required assistance intensity, but this method has some limitations, such as simple evaluation methods, deviation between the assistance effect and the patient's expectations, and insufficient applicability to different patients. Therefore, this paper proposes a new control method, which provides a control strategy with personalized treatment characteristics by estimating and mapping the stiffness of the patient's healthy limb. This method aims to overcome the deficiencies of existing technologies, make rehabilitation training more in line with the patient's personal characteristics and habits, and thus improve the effectiveness and comfort of rehabilitation training. Specifically, the paper proposes a control system that includes an interactive control module in the task space and an inner - loop position control module in the joint space. The interactive control module is based on the quantitative evaluation of movement requirements, while the inner - loop position control module is used to control the position of the pneumatic swing cylinder. By collecting surface electromyography signals (sEMG) and human - machine interaction forces, the researchers constructed an upper - limb end - point stiffness estimation model and designed a parameter identification algorithm. These data are used to quantify the movement requirements of the patient's impaired limb when completing specific actions, and dynamically adjust the rehabilitation training trajectory and assistance force of the robot according to the actual movement ability to achieve AAN control. The experimental results show that the proposed AAN control method can effectively estimate the patient's movement requirements and achieve progressive rehabilitation training.