Abstract:Lead halide perovskite nanocrystals have recently demonstrated great potential as x-ray scintillators, yet they still suffer toxicity issues, inferior light yield (LY) caused by severe self-absorption. Nontoxic bivalent europium ions (Eu<sup>2+</sup>) with intrinsically efficient and self-absorption-free <i>d-f</i> transition are a prospective replacement for the toxic Pb<sup>2+</sup>. Here, we demonstrated solution-processed organic-inorganic hybrid halide BA<sub>10</sub>EuI<sub>12</sub> (BA denotes C<sub>4</sub>H<sub>9</sub>NH<sub>4</sub><sup>+</sup>) single crystals for the first time. BA<sub>10</sub>EuI<sub>12</sub> was crystallized in a monoclinic space group of <i>P</i>2<sub>1</sub>/<i>c</i>, with photoactive sites of [EuI<sub>6</sub>]<sup>4-</sup> octahedra isolated by BA<sup>+</sup> cations, which exhibited high photoluminescence quantum yield of 72.5% and large Stokes shift of 97 nm. These properties enable an appreciable LY value of 79.6% of LYSO (equivalent to ~27,000 photons per MeV) for BA<sub>10</sub>EuI<sub>12</sub>. Moreover, BA<sub>10</sub>EuI<sub>12</sub> shows a short excited-state lifetime (151 ns) due to the parity-allowed <i>d-f</i> transition, which boosts the potential of BA<sub>10</sub>EuI<sub>12</sub> for use in real-time dynamic imaging and computer tomography applications. In addition, BA<sub>10</sub>EuI<sub>12</sub> demonstrates a decent linear scintillation response ranging from 9.21 μGy<sub>air</sub> s<sup>-1</sup> to 145 μGy<sub>air</sub> s<sup>-1</sup> and a detection limit as low as 5.83 nGy<sub>air</sub> s<sup>-1</sup>. The x-ray imaging measurement was performed using BA<sub>10</sub>EuI<sub>12</sub> polystyrene (PS) composite film as a scintillation screen, which exhibited clear images of objects under x-ray irradiation. The spatial resolution was determined to be 8.95 lp mm<sup>-1</sup> at modulation transfer function = 0.2 for BA<sub>10</sub>EuI<sub>12</sub>/PS composite scintillation screen. We anticipate that this work will stimulate the exploration of <i>d-f</i> transition lanthanide metal halides for sensitive x-ray scintillators.
multidisciplinary sciences
What problem does this paper attempt to address?