Evaluating Vascular Depth-Dependent Changes in Multi-Wavelength PPG Signals Due to Contact Force

Joan Lambert Cause,Ángel Solé Morillo,Bruno da Silva,Juan C. García-Naranjo,Johan Stiens
DOI: https://doi.org/10.3390/s24092692
IF: 3.9
2024-04-25
Sensors
Abstract:Photoplethysmography (PPG) is a non-invasive method used for cardiovascular monitoring, with multi-wavelength PPG (MW-PPG) enhancing its efficacy by using multiple wavelengths for improved assessment. This study explores how contact force (CF) variations impact MW-PPG signals. Data from 11 healthy subjects are analyzed to investigate the still understudied specific effects of CF on PPG signals. The obtained dataset includes simultaneous recording of five PPG wavelengths (470, 525, 590, 631, and 940 nm), CF, skin temperature, and the tonometric measurement derived from CF. The evolution of raw signals and the PPG DC and AC components are analyzed in relation to the increasing and decreasing faces of the CF. Findings reveal individual variability in signal responses related to skin and vasculature properties and demonstrate hysteresis and wavelength-dependent responses to CF changes. Notably, all wavelengths except 631 nm showed that the DC component of PPG signals correlates with CF trends, suggesting the potential use of this component as an indirect CF indicator. However, further validation is needed for practical application. The study underscores the importance of biomechanical properties at the measurement site and inter-individual variability and proposes the arterial pressure wave as a key factor in PPG signal formation.
engineering, electrical & electronic,chemistry, analytical,instruments & instrumentation
What problem does this paper attempt to address?
### Problems the Paper Attempts to Solve The main goal of this paper is to elucidate the specific impact patterns of contact force (CF) changes on multi-wavelength photoplethysmographic (MW-PPG) signals. Specifically, the study analyzes the changes in raw signals and their DC (direct current) and AC (alternating current) components during the increase and decrease of contact force by recording MW-PPG signals at 5 wavelengths (470, 525, 590, 631, and 940 nanometers), contact force, skin temperature, and tension measurements derived from contact force from 11 healthy subjects. #### Main Contributions: 1. **Multi-parameter Dataset**: Provides a synchronized dataset of MW-PPG, contact force, and skin temperature measurements for comprehensive data analysis. 2. **Relationship Between CF Changes, Tissue Mechanics, and MW-PPG Signal Evolution**: Explores the relationship between contact force changes, tissue mechanical properties, and the evolution of MW-PPG signals. 3. **Preliminary Correlation Analysis**: Conducts a preliminary investigation into the correlation between contact force and the DC component of MW-PPG signals. ### Summary of the Abstract This paper explores how changes in contact force affect multi-wavelength photoplethysmographic (MW-PPG) signals. By analyzing data from 11 healthy subjects, the study examines the specific impact of contact force on PPG signals. The research finds that different wavelengths respond differently to changes in contact force, and the DC component of all wavelengths (except 631 nanometers) correlates with the trend of contact force, indicating that this component can serve as an indirect indicator of contact force. However, further validation is needed for practical application. Additionally, the study emphasizes the importance of the biomechanical properties of the measurement site and individual differences, and highlights the critical role of arterial pressure waves in the formation of PPG signals.