Degradation of 1,2,3-trichloropropane in aqueous solution by ZVI-enhanced Fenton system: Performances and mechanisms

Jianxiong Gao,Longbin Zhang,Zhiqiang Xu,Xianxian Sheng,Dexiao Li,Yuantian Chen,Mudassir Habib,Shuguang Lyu
DOI: https://doi.org/10.1016/j.jece.2023.110432
IF: 7.7
2023-06-29
Journal of Environmental Chemical Engineering
Abstract:In this research, zero-valent iron (ZVI) was chosen as a reductant in the classic Fenton system to accelerate the generation of Fe(II). The removal of 1,2,3-trichloropropane (TCP) was only 65.3% in classic Fenton system, while with the addition of ZVI its removal could be enhanced to 95.4% in 120 min. Hydroxyl radicals (HO•) was confirmed to be the major radical during TCP degradation by electron paramagnetic resonance (EPR) detection and radical quenching tests. Moreover, the mechanism of TCP degradation in H 2 O 2 /Fe(II)/ZVI system was proposed. In the presence of ZVI, Fe(III) was reduced to Fe(II), further reacted with H 2 O 2 and produced more HO• for TCP removal. 2,3-Dichloro-1-propene and 2-chloro-2-propen-1-ol were the main intermediates in TCP degradation and two possible pathways were proposed. Finally, TCP removal in different solution matrixes and for other chlorinated contaminants removal were tested, revealing the broad-spectrum reactivity and excellent performance of ZVI-enhanced Fenton system in the remediation of chlorinated organic compounds.