Targeted Profiling of Short-, Medium-, and Long-Chain Fatty Acyl-Coenzyme As in Biological Samples by Phosphate Methylation Coupled to Liquid Chromatography–Tandem Mass Spectrometry

Peng Li,Meinrad Gawaz,Madhumita Chatterjee,Michael Lämmerhofer
DOI: https://doi.org/10.1021/acs.analchem.1c00664
IF: 7.4
2021-02-23
Analytical Chemistry
Abstract:Fatty acyl-coenzyme As (acyl-CoAs) are of central importance in lipid metabolism pathways. Short-chain acyl-CoAs are usually part of metabolomics, and medium- to (very) long-chain acyl-CoAs are focus of lipidomics studies. However, owing to the specific complex and amphiphilic nature contributed by fatty acyl chains and hydrophilic CoA moiety, lipidomic analysis of acyl-CoAs is still challenging, especially in terms of sample preparation and chromatographic coverage. In this work, we propose a derivatization strategy of acyl-CoAs based on phosphate methylation. After derivatization, full coverage (from free CoA to C25:0-CoA) and good peak shape in liquid chromatography were achieved. At the same time, analyte loss due to the high affinity of phosphate groups to glass and metallic surfaces was resolved, which is beneficial for routine analysis in large-scale lipidomics studies. A sample preparation method based on mixed-mode SPE was developed to optimize extraction recoveries and allow optimal integration of the derivatization process in the analytical workflow. LC-MS/MS was performed with targeted data acquisition by SRM transitions, which were constructed based on similar fragmentation rules observed for all methylated acyl-CoAs. To achieve accurate quantification, uniformly <sup>13</sup>C-labeled metabolite extract from yeast cells was taken as internal standards. Odd-chain and stable isotope-labeled acyl-CoAs were used as surrogate calibrants in the same matrix. LOQs were between 16.9 nM (short-chain acyl-CoAs) and 4.2 nM (very-long-chain acyl-CoAs). This method was validated in cultured cells and was applied in HeLa cells and human platelets of coronary artery disease patients. It revealed distinct acyl-CoA profiles in HeLa cells and platelets. The results showed that this method can effectively detect acyl-CoAs in biological samples. Considering their central importance in many <i>de novo</i> lipid biosynthesis and remodeling processes, this targeted method offers a valid foundation for future lipidomics analysis of acyl-CoA profiles in biological samples, particularly those concerning metabolic syndrome.The Supporting Information is available free of charge at <a class="ext-link" href="/doi/10.1021/acs.analchem.1c00664?goto=supporting-info">https://pubs.acs.org/doi/10.1021/acs.analchem.1c00664</a>.Method information of high-resolution MS and enhanced product ion scan; tables of matrix effect, extraction recovery, and accuracy; comparison of C17:0-CoA product ion spectra before and after methylation; product ion spectra of selected acyl-CoAs with different collision energies; comparison of cell disruption approaches; autosampler stability test; and representative chromatograms of internal standards and acyl-CoAs determined in HeLa cells (<a class="ext-link" href="/doi/suppl/10.1021/acs.analchem.1c00664/suppl_file/ac1c00664_si_001.pdf">PDF</a>)This article has not yet been cited by other publications.
chemistry, analytical
What problem does this paper attempt to address?