Comparison of pressure controlled, volume controlled, and volume guaranteed pressure controlled modes in prone position in patients operated for lumbar disc herniation: A randomized trial

Ferim Sakize Gunenc,İlkana Seyidova,Sule Ozbilgin,Koray Ur,Volkan Hanci
DOI: https://doi.org/10.1097/md.0000000000037227
IF: 1.6
2024-02-10
Medicine
Abstract:During the operation, the position of the patients and the ventilation management applied may cause some changes in vital parameters. The aim of ideal ventilation is to protect the lungs and provide acceptable gas changes. For this purpose, minute ventilation should be performed without causing any increase in pressure and volume, while at the same time avoiding low expiratory lung volumes. When performing mechanical ventilation, it is important to prevent lung injury caused by barotrauma, volutrauma, atelectrauma, and biotrauma. Changes in functional residual capacity and closure volumes in the supine position and under anesthesia may lead to ventilation-perfusion inequalities and hypoxemia. [ 1 ]
medicine, general & internal
What problem does this paper attempt to address?