Diagnostic accuracy of magnetically guided capsule endoscopy with a detachable string for detecting oesophagogastric varices in adults with cirrhosis: prospective multicentre study
Xi Jiang,Jun Pan,Qing Xu,Yu-Hu Song,Huan-Huan Sun,Cheng Peng,Xiao-Long Qi,Yang-Yang Qian,Wen-Bin Zou,Yang Yang,Shao-Qin Jin,Ben-Song Duan,Shan Wu,Ye Chu,Ding-Hua Xiao,Li-Juan Hu,Jun-Zhi Cao,Jin-Feng Dai,Xiao Liu,Tian Xia,Wei Zhou,Tao Chen,Chun-Hua Zhou,Wei Wu,Shao-Jun Liu,Zhen-Yu Yang,Fen Wang,Lu Zhang,Cheng-Zhong Li,Hao Xu,Jun-Xue Wang,Bo Wei,Yong Lin,Xing Deng,Li-Hong Qu,Ying-Qiu Shen,Hui Wang,Yi-Fei Huang,Hai-Biao Bao,Shuo Zhang,Li Li,Yi-Hai Shi,Xiao-Yan Wang,Duo-Wu Zou,Xin-Jian Wan,Mei-Dong Xu,Hua Mao,Chao-Hui He,Zhen Li,Xiu-Li Zuo,Shui-Xiang He,Xiao-Ping Xie,Jun Liu,Chang-Qing Yang,Cristiano Spada,Zhao-Shen Li,Zhuan Liao
DOI: https://doi.org/10.1136/bmj-2023-078581
2024-03-05
BMJ
Abstract:Abstract Objective To evaluate the diagnostic accuracy and safety of using magnetically guided capsule endoscopy with a detachable string (ds-MCE) for detecting and grading oesophagogastric varices in adults with cirrhosis. Design Prospective multicentre diagnostic accuracy study. Setting 14 medical centres in China. Participants 607 adults (>18 years) with cirrhosis recruited between 7 January 2021 and 25 August 2022. Participants underwent ds-MCE (index test), followed by oesophagogastroduodenoscopy (OGD, reference test) within 48 hours. The participants were divided into development and validation cohorts in a ratio of 2:1. Main outcome measures The primary outcomes were the sensitivity and specificity of ds-MCE in detecting oesophagogastric varices compared with OGD. Secondary outcomes included the sensitivity and specificity of ds-MCE for detecting high risk oesophageal varices and the diagnostic accuracy of ds-MCE for detecting high risk oesophagogastric varices, oesophageal varices, and gastric varices. Results ds-MCE and OGD examinations were completed in 582 (95.9%) of the 607 participants. Using OGD as the reference standard, ds-MCE had a sensitivity of 97.5% (95% confidence interval 95.5% to 98.7%) and specificity of 97.8% (94.4% to 99.1%) for detecting oesophagogastric varices (both P<0.001 compared with a prespecified 85% threshold). When using the optimal 18% threshold for luminal circumference of the oesophagus derived from the development cohort (n=393), the sensitivity and specificity of ds-MCE for detecting high risk oesophageal varices in the validation cohort (n=189) were 95.8% (89.7% to 98.4%) and 94.7% (88.2% to 97.7%), respectively. The diagnostic accuracy of ds-MCE for detecting high risk oesophagogastric varices, oesophageal varices, and gastric varices was 96.3% (92.6% to 98.2%), 96.9% (95.2% to 98.0%), and 96.7% (95.0% to 97.9%), respectively. Two serious adverse events occurred with OGD but none with ds-MCE. Conclusion The findings of this study suggest that ds-MCE is a highly accurate and safe diagnostic tool for detecting and grading oesophagogastric varices and is a promising alternative to OGD for screening and surveillance of oesophagogastric varices in patients with cirrhosis. Trial registration ClinicalTrials.gov NCT03748563 .
medicine, general & internal