Investigations on Hot Air Anti-Icing Characteristics with Internal Jet-Induced Swirling Flow

Yuyang Liu,Xian Yi
DOI: https://doi.org/10.3390/aerospace11040270
IF: 2.66
2024-03-31
Aerospace
Abstract:The tangential jet-induced swirling flow is a highly efficient technology for enhancing heat transfer. This paper explores the application of swirling flow of an airfoil/aero-engine in a hot air anti-icing chamber, aiming to improve the anti-icing performance and achieve a more uniform temperature on the surface. A series of numerical computations adopting the SST k − ω turbulent model was carried out to obtain the internal flow and heat transfer characteristics, as well as the surface temperature distributions, considering water evaporation and solid heat conduction. Three jet arrangements, including impingement jets, offset jets, and swirl jets, were studied and compared, which evidently showed that the swirling effect was helpful to elevate the internal heat transfer. Compared to the impingement jets at the Reynolds number of 40,000, the Nusselt number with the offset jets is increased by 19.5%, while the corresponding Nusselt number of the swirl jets is augmented by 44.3%. The swirling flow significantly elevates the swirl number within the internal chamber, intensifying the vortex strength near the wall and increasing the circumferential velocity, which also results in an augmentation of internal pressure loss. By adopting the swirling internal flow, the temperature distribution on the anti-icing surface is more uniform and is increased by up to about 4.1 K in the leading edge when the internal-to-external temperature difference is 80 K. Simultaneously, the heat absorption of water evaporation and the matches between the internal heat transfer and external icing load are of particular importance to determine the anti-icing performance, and this has been discussed in this paper.
engineering, aerospace
What problem does this paper attempt to address?
### Problems the paper attempts to solve This paper aims to explore the application of internal jet - induced swirl technology in the hot - air anti - icing system to improve anti - icing performance and achieve a more uniform surface temperature distribution. Specifically, the paper mainly focuses on the following points: 1. **Improve heat transfer efficiency**: By introducing swirl technology, enhance the internal heat transfer effect, thereby improving the overall performance of the anti - icing system. 2. **Uniform temperature distribution**: Make the temperature distribution on the anti - icing surface more uniform, reduce local high - temperature or low - temperature areas, and thus improve the anti - icing effect. 3. **Reduce hot - air consumption**: While maintaining high - efficiency anti - icing performance, reduce the demand for hot air provided by the engine, lower the engine load, and improve the overall performance of the aircraft. ### Research background Aircraft icing poses a significant threat to flight safety. Although the existing hot - air anti - icing methods are widely used on wings and engine blades, there are problems of low heat transfer efficiency and high hot - air consumption. Swirl technology, as an efficient heat transfer technology, has been applied in gas turbines and aero - engine blade cooling. This paper attempts to apply swirl technology to the hot - air anti - icing system to solve the above problems. ### Research methods 1. **Numerical simulation**: Use the SST \(k - \omega\) turbulence model for numerical calculation to study the internal flow and heat transfer characteristics under different injection methods (impingement injection, offset injection, swirl injection). 2. **Experimental verification**: Verify the accuracy of numerical simulation by comparing with the data in existing literature. 3. **Comprehensive analysis**: Consider the endothermic effect of water evaporation and the problem of internal and external heat transfer matching, and conduct a comprehensive anti - icing performance analysis. ### Main results 1. **Improvement in heat transfer performance**: Compared with impingement injection, offset injection and swirl injection increase the Nusselt number (Nu) by 19.5% and 44.3% respectively, indicating that swirl injection has a significant heat transfer enhancement effect. 2. **Uniform temperature distribution**: Swirl injection makes the temperature distribution on the anti - icing surface more uniform, especially in the leading - edge area, where the temperature is increased by about 4.1 K. 3. **Increased pressure loss**: Although swirl injection improves the heat transfer performance, it also leads to greater pressure loss, and the heat transfer effect and pressure loss need to be balanced during design. ### Conclusion The swirl injection technology has significant advantages in the hot - air anti - icing system. It can effectively improve the anti - icing performance and the uniformity of the surface temperature, and at the same time reduce the consumption of hot air. Future research can further optimize the design of swirl injection to achieve better anti - icing effects.