Fouling and Corrosion Behavior of Nickel–Graphene/Polytetrafluoroethylene Composite Hydrophobic Coating

Muhammad Zafar Ullah,Mingyan Liu,Jizhe He,Muhammad Chawla
DOI: https://doi.org/10.1080/01457632.2024.2368425
IF: 2.3
2024-06-26
Heat Transfer Engineering
Abstract:Fouling and corrosion mitigation in heat exchange equipment remains a significant challenge. Numerous research techniques have been developed to address this issue. Surface modification is an effective method for preventing fouling and corrosion. This work used electrodeposition and dip coating techniques to create a nickel–graphene/polytetrafluoroethylene (NGP) composite hydrophobic coating. The field emission scanning electron microscopy, contact angle analyzer, X-ray photoelectron spectroscopy, energy dispersive spectroscopy, and atomic force microscopy techniques were used to investigate the surface morphologies, wettability, binding energies, chemical compositions, and roughness, respectively. The water contact angle (WCA) of the NGP hydrophobic coating (147.1° ± 2.2°) was significantly higher than the WCA of carbon steel (76.8° ± 1.6°). Electrochemical impendence spectroscopy results showed that the NGP composite hydrophobic coating has improved anti-corrosion performance with a greater capacitive curve, a higher modulus of impedance value at low frequency, and increased charge transfer resistance. Furthermore, fouling testing at various temperatures exhibited the anti-fouling and anti-corrosion behavior of the NGP composite hydrophobic coating, suggesting possible uses in practical applications.
engineering, mechanical,thermodynamics,mechanics