Managing hardware-related metal artifacts in MRI: current and evolving techniques

Georg C. Feuerriegel,Reto Sutter
DOI: https://doi.org/10.1007/s00256-024-04624-4
2024-02-21
Skeletal Radiology
Abstract:Abstract Magnetic resonance imaging (MRI) around metal implants has been challenging due to magnetic susceptibility differences between metal implants and adjacent tissues, resulting in image signal loss, geometric distortion, and loss of fat suppression. These artifacts can compromise the diagnostic accuracy and the evaluation of surrounding anatomical structures. As the prevalence of total joint replacements continues to increase in our aging society, there is a need for proper radiological assessment of tissues around metal implants to aid clinical decision-making in the management of post-operative complaints and complications. Various techniques for reducing metal artifacts in musculoskeletal imaging have been explored in recent years. One approach focuses on improving hardware components. High-density multi-channel radiofrequency (RF) coils, parallel imaging techniques, and gradient warping correction enable signal enhancement, image acquisition acceleration, and geometric distortion minimization. In addition, the use of susceptibility-matched implants and low-field MRI helps to reduce magnetic susceptibility differences. The second approach focuses on metal artifact reduction sequences such as view-angle tilting (VAT) and slice-encoding for metal artifact correction (SEMAC). Iterative reconstruction algorithms, deep learning approaches, and post-processing techniques are used to estimate and correct artifact-related errors in reconstructed images. This article reviews recent developments in clinically applicable metal artifact reduction techniques as well as advances in MR hardware. The review provides a better understanding of the basic principles and techniques, as well as an awareness of their limitations, allowing for a more reasoned application of these methods in clinical settings.
radiology, nuclear medicine & medical imaging,orthopedics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is the artifact problem caused by metal implants in magnetic resonance imaging (MRI). Specifically: 1. **Signal loss and geometric distortion**: Due to the difference in magnetic susceptibility between metal implants and surrounding tissues, problems such as image signal loss, geometric distortion, and failure of fat suppression occur. These problems will seriously affect the accuracy of diagnosis, especially in the evaluation of patients after joint replacement. 2. **Increasing clinical demand**: With the aging of the population and the increase in the number of joint replacement surgeries, more accurate imaging tools are needed to evaluate the tissue conditions around metal implants to assist in clinical decision - making and dealing with postoperative complications. 3. **Limitations of existing technologies**: Traditional imaging techniques are not effective near metal implants, so new hardware and software methods need to be explored to reduce these artifacts and improve image quality. ### Main content of the paper The paper reviews the latest progress and technologies in reducing metal artifacts in MRI in recent years, including improvements in both hardware and software. The main content includes: - **Hardware improvements**: Such as high - density multi - channel radio - frequency (RF) coils, parallel imaging techniques, and gradient correction. These techniques can enhance the signal, accelerate image acquisition, and minimize geometric distortion. - **Application of new materials**: Use of implants with matched magnetic susceptibility (such as titanium alloys) and low - field - strength MRI to reduce the difference in magnetic susceptibility. - **Sequence optimization**: Reduce artifacts by adjusting MRI sequence parameters (such as bandwidth optimization, view - angle tilting, slice encoding, etc.). - **Advanced reconstruction algorithms**: Such as iterative reconstruction algorithms, deep - learning methods, and post - processing techniques, which are used to estimate and correct artifact - related errors in reconstructed images. ### Key point summary - Technologies such as bandwidth optimization, view - angle tilting, or slice encoding have significantly improved the quality of MRI images around metal implants. - STIR imaging provides better fat suppression in the presence of metal implants, but has a lower signal - to - noise ratio (SNR). - The slice - encoding technique combined with compressed sensing can accurately image the complications around the prosthesis. These improvements make MRI imaging around metal implants more reliable and provide strong support for clinical diagnosis.