Bladder perforation due to laparoscopic peritoneal dialysis catheterization: A case report and literature review

Xiaoyun Shao,Yanling Zhang,Weixing Xu
DOI: https://doi.org/10.1097/md.0000000000040444
IF: 1.6
2024-11-13
Medicine
Abstract:Peritoneal dialysis (PD), offering the benefits of stable hemodynamics, a low risk of bloodstream infection, preservation of residual renal function, and enhancement of quality of life, [ 1 ] has emerged as the preferred modality for renal replacement therapy in patients with end-stage renal disease. Percutaneous puncture catheterization, surgical catheterization, and laparoscopic catheterization are the most common methods for PD catheterization. Advancements in PD catheterization technology have led to a gradual decrease in the incidence of complications related to catheterization. However, these complications continue to be a primary cause of treatment failure in PD. The main complications include infection-related issues (exit site and tunnel infections) and mechanical problems (catheter displacement or occlusion, dialysate leakage, hernia, internal organ injury, and bleeding). [ 2 ] Hence, timely identification and correction of catheter-related complications are essential for enhancing the prognosis of PD patients.
medicine, general & internal
What problem does this paper attempt to address?