Ce(III)-modulation over non-enzymatic Pt/CeO 2 /GO biosensor with outstanding sensitivity and stability for lactic acid detection
Luyao Zhang,Fuli Tian,Huan Li,Jiangman Meng,Qi Liu,Xiaoqian Guo,Yun Qiu,Jun Zhang,Changyan Li
DOI: https://doi.org/10.1016/j.jre.2022.07.014
IF: 4.632
2022-08-04
Journal of Rare Earths
Abstract:Highlights • A series of non-enzymatic biosensor has been fabricated and applied for detecting lactic acid based on graphene functionalized Pt/CeO 2 /GO. • Ce(III)-modulation causes the super charge-transfer and synergistic effect, which makes Pt/CeO 2 /GO non-enzymatic biosensor have excellent sensing performance. • The Pt/CeO 2 /GO non-enzymatic biosensor still possesses high stability and reproducibility after one year. • The pathway of electronical oxidation of lactic acid and the mechanism of synergistic effect are proposed. • The results of standard addition method in real samples show that the lactic acid detection data of Pt/CeO 2 /GO non-enzyme biosensor has high reliability. A series of non-enzymatic graphene functionalized biosensors were developed via deposition precipitation method for lactic acid detection, which were characterized by transmission electron microscopy (TEM), Raman spectroscopy, X-ray photoelectron spectroscopy (XPS), electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV), gas chromatography-mass spectrometry, liquid chromatography-mass spectrometry, and proton nuclear magnetic resonance ( 1 H NMR). The electrochemical performances of the non-enzymatic biosensors were measured by means of the electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) method. The comprehensive analysis of structures exhibits that Pt, CeO 2 , and GO components interact with each other. During the storing and releasing oxygen, the valence ratio of Ce 3+ /Ce 4+ and the number of oxygen vacancies in CeO 2 change accordingly, which could be conducive to increasing electronic transmission capacity and finally lead to the improvement of electrocatalytic performance. Among them, the Pt/CeO 2 /GO biosensor containing 0.47 at% platinum exhibits an excellent electrochemical detection performance with high sensitivity of 12.3 μA/(mmol/L/cm 2 ) and a low limit of detection (LOD) of 5.12 μmol/L in a wide linear range from 10 to 900 μmol/L. In addition, the proposed biosensor possessed a promising anti-interference capability, as well as a high stability and a good reproducibility, which was assessed by testing the cyclic voltammogram in 0.1 mol/L lactic acid one year later. The underlying mechanism has been proposed for electrochemical oxidation of LA to carbon dioxide and acetic acid with the synergistic effect among Pt, CeO 2 , and GO. Furthermore, the results of the standard addition method in real samples (human serum and urine samples) reveal that the lactic acid detection of the non-enzymatic Pt/CeO 2 /GO biosensor is accompanied by a high reliability. Thus, it would be a valuable biosensor for in vitro detection of lactic acid level in clinical samples. Graphical abstract A change in the ratio of Ce 3+ /Ce 4+ generates oxygen vacancies, which makes Pt/CeO 2 /GO non-enzymatic biosensor possess outstanding sensing performance for lactic acid detection. The underlying mechanism was proposed for electrochemical oxidation of LA to carbon dioxide and acetic acid with the synergistic effect among Pt, CeO 2 , and GO. Download : Download high-res image (266KB) Download : Download full-size image
chemistry, applied