4D-Printed Temperature-Controlled Flow-Actuated Solid-Phase Extraction Devices

Chun-Yi Wu,Jyun-Ran Chen,Cheng-Kuan Su
DOI: https://doi.org/10.1021/acs.analchem.1c01703
IF: 7.4
2021-07-09
Analytical Chemistry
Abstract:Four-dimensional printing (4DP) technologies can extend the functionality and applicability of manufactured analytical devices through employing stimuli-responsive materials. In this study, we used a photocurable resin of stimuli-responsive shape-memory polymers and digital light processing three-dimensional printing (3DP) to fabricate a smart sample pretreatment device featuring a solid-phase extraction (SPE) column and a temperature-controlled flow-actuated valve. Through manipulation of the temperatures and flow rates of the sample, eluent, and rinsing streams, we used this 4D-printed SPE device to extract Mn, Co, Ni, Cu, Zn, Cd, and Pb ions from high-salt content samples and remove the sample matrix prior to their determination by inductively coupled plasma mass spectrometry. After optimizing the valve design and operation and the analytical scheme, this device displayed competitive analytical performance—the method detection limits (MDLs) ranged from 0.7 to 22.1 ng L<sup>–1</sup> for these metal ions (the MDLs ranged from 0.5 to 18.8 ng L<sup>–1</sup> when validating the same printed SPE column using an online automatic system equipped with electric switching valves). Furthermore, we performed analyses of these metal ions in three reference materials (CASS-4, 1643f, and 2670a) and spike analyses of collected samples (seawater, ground water, river water, and human urine) to confirm the reliability and applicability of this analytical method. For the first time, 4DP has been used to fabricate a multi-functional, stimuli-responsive sample pretreatment device displaying analytical performance equal to that of a commercial apparatus. This novel approach builds upon the functionality and diversity of 3DP-enabling devices with the goal of developing more efficient analytical schemes.The Supporting Information is available free of charge at <a class="ext-link" href="/doi/10.1021/acs.analchem.1c01703?goto=supporting-info">https://pubs.acs.org/doi/10.1021/acs.analchem.1c01703</a>.Detailed dimensions of the designed SPE device; photographs of the 4D-printed SPE device at the sample loading step, elution step, and rinsing step; step-by-step schematic representations of the used online automatic analytical system equipped with the printed SPE column and three electric switching valves; thermal analysis of the cured resin; infrared spectrum of the cured resin; relative signal intensities of the extracted metal ions plotted with respect to the evacuation flow rate, the concentration of HNO<sub>3</sub> in the eluent, the temperature of the eluent, the number of cuboids packed per layer, the layer of interlacing cuboids, the concentration of NaCl, and the co-existing interference ions; operating sequence of the online automatic analytical system; optimized conditions for the developed analytical scheme using the 4D-printed SPE device; conditions used to operate the online automatic analytical system; analytical data obtained when using the proposed analytical scheme with the 4D-printed SPE device for the analysis of reference materials; and analytical results obtained from real natural water and urine samples when using the proposed analytical scheme with the 4D-printed SPE device (<a class="ext-link" href="/doi/suppl/10.1021/acs.analchem.1c01703/suppl_file/ac1c01703_si_001.pdf">PDF</a>)This article has not yet been cited by other publications.
chemistry, analytical
What problem does this paper attempt to address?