Comparative analysis of degradation mechanisms in HT-PEM fuel cells under start–stop and load cycling with hydrogen and nitrogen-diluted feeds

Mengfan Zhou,Na Li,Deyong Wang,Samuel Simon Araya,Vincenzo Liso
DOI: https://doi.org/10.1016/j.ijhydene.2024.04.028
IF: 7.2
2024-04-11
International Journal of Hydrogen Energy
Abstract:The integration of reformers into high-temperature polymer electrolyte membrane (HT-PEM) fuel cells presents a significant opportunity to improve fuel flexibility and cost-effectiveness. To understand their degradation, we applied two start–stop cycling procedures: one with pure H 2 and another with an 80 vol % H 2 and 20 vol % N 2 mix to simulate reformate gas. We also performed a load cycling test with H 2 as anode gas. The results indicated that degradation rate of pure H 2 start–stop cycling showed 306 μ V h −1 , while load cycling demonstrated a degradation rate of 19.7 μ V h −1 for the current density of 0.2 A cm −2 , and 88.2 μ V h −1 for the current density of 0.4 A cm −2 . Start–stop cycling with diluted gas resulted in a constant voltage drop with a degradation rate of 3.129 mV h −1 . Electrochemical impedance spectroscopy (EIS) indicated an increased ohmic resistance during start–stop cycling and higher charge transfer (high-frequency) and mass transport (low-frequency) resistance with nitrogen introduction. Scanning electron microscope results confirmed MEA degradation. In conclusion, start–stop cycling and anode gas dilution are stressors that accelerate HT-PEM fuel cell degradation, reducing its lifetime.
energy & fuels,electrochemistry,chemistry, physical
What problem does this paper attempt to address?