Dosimetric Considerations for 177Lu-DOTATATE Therapy in a Patient With Chronic Renal Failure Under Hemodialysis

Sarah Chaib,Perrine Tylski,Choaib Lachachi,Tassadit Keniza,Elise Levigoureux
DOI: https://doi.org/10.1097/rlu.0000000000005262
IF: 10.6
2024-06-04
Clinical Nuclear Medicine
Abstract:This case report explores the use of 177Lu-DOTATATE in a hemodialysis patient. For the first time, this study assesses the average dose received by the bone marrow, the primary organ at risk, using an original double estimation method through independently acquired imaging and biological samples counting data. Despite elevated doses, the absorbed doses to the bone marrow (0.662–0.740 Gy) were within safe limits. Radiation protection measurements for staff were also compliant. This work supports that effective early dialysis and systematic personalized dosimetry are crucial for hemodialysis patients undergoing 177Lu-PRRT due to their variability (residual excretion, treatment history, etc).
radiology, nuclear medicine & medical imaging
What problem does this paper attempt to address?