Hybrid NV center magnetometer with directional vector resolution based on magnetic flux concentrators

Qimeng Wang,Doudou Zheng,Xinyu Liu,Junzhi Zhao,Yuanyuan Shen,Hao Guo,Zhonghao Li,Jun Tang,Zongmin Ma,Yanjun Li,Jun Liu
DOI: https://doi.org/10.1109/jsen.2023.3274755
IF: 4.3
2023-01-01
IEEE Sensors Journal
Abstract:Since the introduction of Hall magnetometers, different types of magnetometers have been widely used. Among them, magnetometers based on nitrogen-vacancy (NV) centers in diamonds are promising room-temperature solid-state sensors. Their sensitivity to low-frequency (< 10 Hz) magnetic fields has been reported to be currently at the nT level. Still, limitations in the detectable spatial range hinder their potential applications in medical imaging, earth sciences, and navigation. The most recent sensitivity enhancement technique involves using high-permeability flux concentrators with a unique magnetic field amplification structure that can cause the NV magnetometer to lose its vector detection capabilities. To address this limitation, we proposed a hybrid magnetometer based on a diamond-based hetero-NV center, which collects magnetic flux over a larger area and concentrates it in the diamond magnetometer, from which the magnetic field vector can be calculated by measuring the specific magnetic field direction vector. The low-frequency sensitivity of 90 pT∙Hz-1/2 under conventional ambient conditions has been solved by inserting NV-doped diamond blocks between four permalloy concentrators in a triangular structure, which solves the vector deficiency problem of traditional magnetic concentrators. High-sensitivity real-time variation acquisition of the magnetic field signal has been achieved by applying an AC magnetic field in combination with modulation and demodulation methods.
engineering, electrical & electronic,instruments & instrumentation,physics, applied
What problem does this paper attempt to address?
The problems that this paper attempts to solve are as follows: The diamond magnetometer based on the nitrogen - vacancy (NV) center has limited spatial resolution in low - frequency magnetic field detection, and although the use of high - permeability magnetic flux concentrator (MFC) technology can enhance sensitivity, it will cause the magnetometer to lose its vector detection ability. To solve these problems, the paper proposes a hybrid magnetometer based on heterogeneous NV centers. By designing a new structural shape, the vector resolution of the magnetometer is maintained while the sensitivity is improved. Specifically, the paper focuses on the following points: 1. **Improving sensitivity**: By inserting diamond blocks doped with NV centers into the triangular structure between four permalloy concentrators, a low - frequency sensitivity of 90 pT·Hz\(^{-1/2}\) is achieved. 2. **Restoring vector detection ability**: The traditional MFC technology will cause the magnetometer to lose its vector detection ability, and the proposed hybrid magnetometer solves this problem through a specific magnetic field direction vector measurement method. 3. **Acquiring real - time signal changes**: By applying an alternating magnetic field combined with modulation - demodulation technology, high - sensitivity acquisition of real - time magnetic field signal changes is achieved. These improvements make the hybrid magnetometer have more extensive application potential in fields such as medical imaging, earth science, and navigation.