Mechanical and Geometric Characterization of a Novel 2-Ply Vacuum-Pressed Biological Scaffold Patch Design for Posterior Mitral Valve Reconstruction

Johannes H. Jedrzejczyk,Frederik T. Andersen,Jacob Petersen,Alexander Emil Kaspersen,Urjosee Sahana,Søren N. Skov,Jens T. Væsel,J. Michael Hasenkam,Marcell J. Tjørnild
DOI: https://doi.org/10.1007/s12265-024-10572-0
2024-10-30
Journal of Cardiovascular Translational Research
Abstract:To assess the mechanical properties of small intestinal submucosal extracellular matrix (SIS-ECM) iterations and choose the optimal version for evaluating functional geometrics after posterior mitral valve reconstruction. Four SIS-ECM versions (2- and 4-ply vacuum-pressed and lyophilized) underwent uniaxial tensile testing. A posterior mitral valve reconstruction patch was developed based on MRI scans (n = 5). Posterior mitral valve reconstruction using 2-ply vacuum-pressed SIS-ECM was performed (n = 7), and geometrics were evaluated using a modified left heart simulator. The vacuum-pressed iterations displayed superior maximum stress values compared to lyophilized (2-ply: median [IQR], 15.8 [15.2–19.0] vs 7.9 [7.3–8.3] MPa, p < 0.001; 4-ply: median (IQR), 15.8 –[14.6–22.0] vs 7.9 [7.6–8.4] MPa). All reconstructed valves were competent with preserved total leaflet area, but individual leaflet segment areas were redistributed. Posterior mitral valve reconstruction with our 2-ply vacuum-pressed SIS-ECM patch design was feasible in vitro. Further in vivo evaluation is warranted.
cardiac & cardiovascular systems,medicine, research & experimental
What problem does this paper attempt to address?