Damage tolerance and collapse mechanism of failed prestressing steel strands in a 50-year-old urban viaduct

Maricely De Abreu,Mihaela Iordachescu,Patricia Santos,Andrés Valiente
DOI: https://doi.org/10.1016/j.engfailanal.2024.108101
IF: 4
2024-05-01
Engineering Failure Analysis
Abstract:Localized cracking of concrete facing was recurrently detected inan urban viaduct opened to traffic 50 years ago without successive repairs having taken effect. The viaduct was a post-tensioned reinforced concrete structure, with a partial dismantlement of the affected area revealing prestressing tendons with corrosion damage and a certain number of broken strands. A failure analysis was performed on the basis of tensile testing and microstructural and fractographical characterization of the prestressing steel in two conditions: damage-free and as-removed from the viaduct. The comparison of the results thus allowed the quality of the steel to be excluded as a failure cause. Such a cause was attributed to the long-term effects of constructive procedures, which are today known to be insufficiently effective concerning the protective barriers of the tendon strands against the access of aggressive media.
engineering, mechanical,materials science, characterization & testing
What problem does this paper attempt to address?