Quantification of porcine lower thoracic spinal cord morphology with intact dura mater using high‐resolution μCT

Justin Chin,Megan L. Settell,Meagan K. Brucker‐Hahn,Daniel Lust,Jichu Zhang,Aniruddha R. Upadhye,Bruce Knudsen,Ashlesha Deshmukh,Kip A. Ludwig,Igor A. Lavrov,Andrew R. Crofton,Scott F. Lempka,Mingming Zhang,Andrew J. Shoffstall
DOI: https://doi.org/10.1111/jon.13239
2024-10-12
Journal of Neuroimaging
Abstract:Background and Purpose Spinal cord stimulation (SCS) is approved by the Food and Drug Administration for treating chronic intractable pain in the back, trunk, or limbs through stimulation of the dorsal column. Numerous studies have used swine as an analog of the human spinal cord to better understand SCS and further improve its efficacy. We performed high‐resolution imaging of the porcine spinal cord with intact dura mater using micro‐computed tomography (μCT) to construct detailed 3‐dimensional (3D) visualizations of the spinal cord and characterize the morphology of the dorsal and ventral rootlets. Methods We obtained spinal cords from Yorkshire/Landrace crossbred swine (N = 7), stained samples with osmium tetroxide, and performed μCT imaging of the T12‐T15 levels at isotropic voxel resolutions ranging from 3.3 to 50 μm. We measured the anatomical morphology using the 3D volumes and compared our results to measurements previously collected from swine and human spinal cords via microdissection techniques in prior literature. Results While the porcine thoracic‐lumbar spinal cord is a popular model for SCS, we highlight multiple notable differences compared to previously published T8‐T12 human measurements including rootlet counts (porcine dorsal/ventral: 12.2 ± 2.6, 26.6 ± 3.4; human dorsal/ventral: 5.3 ± 1.3, 4.4 ± 2.4), rootlet angles (porcine ventral‐rostral: 161 ± 1°, ventral‐caudal: 155 ± 6°, dorsal‐rostral: 148 ± 9°, dorsal‐caudal: 142 ± 6°; human ventral‐rostral: 170 ± 3°, ventral‐caudal: 22 ± 10°, dorsal‐rostral: 171 ± 3°, dorsal‐caudal: 15 ± 7°), and the presence and count of dorsal rootlet bundles. Conclusions Detailed measurements and highlighted differences between human and porcine spinal cords can inform variations in modeling and electrophysiological experiments between the two species. In contrast to other approaches for measuring the spinal cord and rootlet morphology, our method keeps the dura intact, reducing potential artifacts from dissection.
radiology, nuclear medicine & medical imaging,clinical neurology,neuroimaging
What problem does this paper attempt to address?